Screen
With this button a hardcopy from the actual screen will be made. This also includes,
graphical information.
REC
With this button you activate three extra windows with the values: MAX; MIN en AVG.
You are able to measure over a total period of time the MAX (=Maximum) value; the MIN
(=Minimum) and the AVG (=Average) values will be displayed.
CMP
With the edit button you can adjust the HI-limit and LO-limit. In the last window the
Judgement in relation to the HI or LO value is displayed: HI when the upper limit is
exceeded and LO when the lower-limit is exceeded.
REL
After clicking on the Edit button you are asked for a Reference value. The ERROR field
now displays the difference in relation with this reference. The value can be positive or
negative.
Graph screen
Setup
You can change the X- and Y-axes of the graphical screen. The Y-ax changes the range
and the X-ax changes the readings. You can change to 280; 350; 700 and 1400 readings.
The total result also depends on the S/Time as mentioned before. Switch on the graphical
screen by pressing the ON button. The button will change to red. If the screen is
completely filled it will switch off automatically and the OFF button changes to red. The
screen will be cleared with the CLEAR button. Just start it from the beginning with ON.
Leave the program by clicking the left upper button from the screen. You are asked to
save the Default values. Just click on Yes if you prefer this. The next time you start the
program all previous settings will be regained.