EasyManua.ls Logo

Dynaxo DynaCook X2 - Page 42

Dynaxo DynaCook X2
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
42
Alarm condition on the Control Panel
Signal Comments
No. Cause
Light Sound
4
Problems with hot air
exhaust system (incorrect
operation of the control
equipment)
C letter constantly on
Short beep every 2
seconds
1. Switch off power supply.
2. Check if the hot air outlet is not covered or blocked.
3. Switch on power supply.
4. If the abnormalities described in point 2 above do not occur but the C alarm condition is still
on, switch off power supply, close the gas valve and call service center.
5
Electric circuit failure
(incorrect operation of the
control equipment)
E letter constantly on
Short beep every 2
seconds
1. Switch off the hob power supply for at least 20 seconds and close the gas valve.
2. Check the parameters of power supply. If the parameters are correct, open the gas valve,
switch on power supply.
3. If after power supply is switch on again, E letter is still displayed, switch off power supply,
close the gas valve and call service center.