8
4.0 TECHNICAL DATA
4.1 Ordering Guide
1392-1-1 Dual Alarms with a 24Vdc Power Supply
1392-2-1 Dual Alarms and Analog Retrans with a 24Vdc Power Supply
1392-3-1 Dual Alarms and MODbus/JBus Comms with a 24Vdc Power Supply
1392-4-1 Dual Alarms, Analog Retrans and MODbus/JBus Comms with 24Vdc
Power Supply
1392-1-3 Dual Alarms with a 85 to 264Vac Power Supply
1392-2-3 Dual Alarms and Analog Retrans with a 85 to 264Vac Power Supply
1392-3-3 Dual Alarms and MODbus/JBus Comms with a 85 to 264Vac Power
Supply
1392-4-3 Dual Alarms, Analog Retrans & MODbus/JBus Comms with 85 to 264Vac
Power Supply
4.2 Specifications
4.2.1 General
Protection Rating: VO Rated fire retardant material
Bezel designed and tested IP65 compliant for indoor locations
Sleeve IP20 compliant
Terminal block IP20 compliant
Installation is IP65 compliant when specified gasket is used
Dimensions: 48 mm high x 96 mm wide x 99.3 mm deep
(1.89” high x 3.78” wide x 3.9” deep)
1/8 DIN per DIN 43700
Less than 105 mm depth from front of panel
Installation: Panel mounted, secured by 2 mounting clips
Cut-out : 45 mm high x 92 mm wide, + 0.8 mm/-0 mm
(1.77” high x 3.62” wide, +0.03”/-0”)
Rear Terminal Block: 24 screw terminals with safety covers
Display: 5 red LED digits, 13.2 mm high
7 segments plus decimal point
Indicators: 3 amber LEDs for unit indication (°C / °F / PK)
2 red LEDs for alarm annunciator function
1 green LED for local/remote control indication
Keyboard: Four domed buttons
Sample Rate: 10 Hz signal & > 0.5 Hz autozero
Common Mode Rejection: Minimum 120 dB at 50 or 60 Hz