G
Gail MillsAug 3, 2025
What to do if Dynon Avionics GPS clock setting is lost?
- LLori RamseyAug 3, 2025
If the Dynon Avionics GPS clock setting is lost, verify that the 'Keep Alive' power is supplied to the unit at all times.
What to do if Dynon Avionics GPS clock setting is lost?
If the Dynon Avionics GPS clock setting is lost, verify that the 'Keep Alive' power is supplied to the unit at all times.
How to fix a black screen on my Dynon Avionics GPS?
If the Dynon Avionics GPS screen stays black when power is applied, verify that the master power is connected and that the master power is above 10 volts.
What to do if my Dynon Avionics GPS EMS-D10 displays a blue screen?
If your Dynon Avionics GPS EMS-D10 displays a continuous or blinking blue screen, ensure that your power supply can supply at least 2 amps and that it is at least 10 volts. If the unit does not operate normally after verifying these conditions, contact Dynon Avionics.
operating temperature | -22° to 122° F (-30° to 50° C) |
---|
voltage range | 10 - 30 Vdc |
---|---|
typical power consumption | 8 watts |
maximum power consumption | 10 watts |
screen type | AMLCD, TFT (Thin Film Transistor) |
---|---|
backlight brightness | 450 nits |
screen size | 3.8” diagonal (96 mm) |
screen resolution | 320 x 240 color pixels |