6.3 Summary Of Command Messages
Command ASCII Hex Type (see below)
HPA type? 0 30 US
Status? 1 31 US
Enable manual redundancy mode 5 35 UC
Enable auto redundancy mode 6 36 UC
This HPA to antenna 7 37 UC
This HPA to load 8 38 UC
Set low power alarm A 41 UC+p
Set high power alarm B 42 UC+p
Warm-up time? C 43 US
Set attenuator D 44 UC+p
Enable RF E 45 UC
Helix record top of file F 46 UC
Next Ihlx record? G 47 US
Helix current? H 48 US
Input power? (see note) I 49 US
Elapsed hours? J 4A US
Go to local L 4C UC
Inhibit RF N 4E UC
Off O 4F
UC
Forward power? P 50 US
Remote enable R 52 UC
Standby S 53 UC
Reflected power? (see note) T 54 US
Attenuator? U 55 US
High power alarm? V 56 US
Low power alarm? W 57 US
Transmit X 58 UC
Set address Y 59 UC+p
Set baud rate Z 5A UC+p
Type:
UC user command
UC+p user command with parameter
US user status/data request
Note: Input power and reflected power are not monitored.
Data requests will be serviced with the HPA in either ‘local’ or ‘remote’ mode.
However, for other commands to be executed, (with the exception of ‘remote
enable’) the HPA must be in ‘remote’ mode. Commands will be rejected as
unexecutable with the HPA in ‘local’ mode.