ASCII: 5ACK45H 12.4mA5ETX4M
Hex: 06 35 48 31 32 2E 34 6D 41 03 4D
6.4.3 Universal Command Messages Requesting Data
Command ASCII Hex
HPA type? 0 30h
Command: Gen: 5STX4 address 0 5ETX4 checksum
ASCII: 5STX4505ETX45EOT4
Hex: 02 35 30 03 04
Response: Gen: 5ACK4 address 0 mmmmnn 5ETX4 checksum
ASCII: 5ACK4506315015ETX45NUL4
Hex: 06 35 30 36 33 31 35 30 31 03 00
The amplifier type is returned as 631501. N6315 operating with control software issue
01.
Command ASCII Hex
Status? 1 31h
Command: Gen: 5STX4 address 1 5ETX4 checksum
ASCII: 5STX4515ETX45ENQ4
Hex: 02 35 31 03 05
Response: Gen: 5ACK4 address 1 D1 D2 D3 D4 D5 D6 D75ETX4 checksum
ASCII: 5ACK451P@A@@A@5ETX4Q
Hex: 06 35 31 50 40 41 40 40 41 40 03 51