Do you have a question about the Eagle ECON Series and is the answer not in the manual?
Specifies the model name of the weighing scale.
Details the type of serial communication interface used by the scale.
Indicates the maximum effective communication distance for the serial interface.
Specifies the required voltage and frequency for the scale's power input.
Defines the acceptable range of ambient temperatures for scale operation.
Indicates the maximum permissible level of humidity for scale operation.
States the scale's internal resolution, indicating its measurement precision.
Details the pinout and color coding for connecting the load cell to the scale.
Outlines the pin configuration for the RS-232 serial communication cable.
Function for zeroing the scale and incrementing values during setting.
Function for taring weight and decrementing values during setting.
Used for data accumulation, recalling data, and making selections.
Enters counting mode and serves as an enter key for selections.
Toggles the display between Net and Gross weight values.
Enables counting of similar items using predefined sample sizes (10-500 pieces).
Allows accumulation of weights and tracks the number of accumulations up to 999.
Allows adjustment of the display's update speed from SPd-1 (fastest) to SPd-5 (slowest).
Configures data transmission formats (tr-01 to tr-13) for RS-232 communication.
Sets the communication speed (baud rate) for RS-232, from 1200 to 9600.
Selects the type of data (OUT-N, OUT-G, OUT-t) to be output via RS-232.
Automatically tares the scale when a stable non-zero weight is present for 3 seconds.
Configures the scale to perform zeroing automatically upon power-on.
Displays and holds the maximum weight measured during a weighing session.
Sets the time duration (01-99 min) before the scale enters sleep mode.
Configures the zero locking sensitivity based on a number of divisions (01-99).
Allows setting a programmable factor for converting weight measurements to liters.
Selects the time duration (Stb-1 to Stb-3) for the scale to consider a reading stable.
Specifies the model name of the weighing scale.
Details the type of serial communication interface used by the scale.
Indicates the maximum effective communication distance for the serial interface.
Specifies the required voltage and frequency for the scale's power input.
Defines the acceptable range of ambient temperatures for scale operation.
Indicates the maximum permissible level of humidity for scale operation.
States the scale's internal resolution, indicating its measurement precision.
Details the pinout and color coding for connecting the load cell to the scale.
Outlines the pin configuration for the RS-232 serial communication cable.
Function for zeroing the scale and incrementing values during setting.
Function for taring weight and decrementing values during setting.
Used for data accumulation, recalling data, and making selections.
Enters counting mode and serves as an enter key for selections.
Toggles the display between Net and Gross weight values.
Enables counting of similar items using predefined sample sizes (10-500 pieces).
Allows accumulation of weights and tracks the number of accumulations up to 999.
Allows adjustment of the display's update speed from SPd-1 (fastest) to SPd-5 (slowest).
Configures data transmission formats (tr-01 to tr-13) for RS-232 communication.
Sets the communication speed (baud rate) for RS-232, from 1200 to 9600.
Selects the type of data (OUT-N, OUT-G, OUT-t) to be output via RS-232.
Automatically tares the scale when a stable non-zero weight is present for 3 seconds.
Configures the scale to perform zeroing automatically upon power-on.
Displays and holds the maximum weight measured during a weighing session.
Sets the time duration (01-99 min) before the scale enters sleep mode.
Configures the zero locking sensitivity based on a number of divisions (01-99).
Allows setting a programmable factor for converting weight measurements to liters.
Selects the time duration (Stb-1 to Stb-3) for the scale to consider a reading stable.
The EAGLE ECON series Digital Weighing Scale is a high-performance and economical weighing device designed for fast and accurate measurements. Building on over 97 years of weighing scale manufacturing expertise, the ECON Series incorporates High Precision Load Cells and highly reliable electronic boards, first introduced by EAGLE in 1976. This series represents a robust product range with improved reliability, ensuring consistent and dependable operation.
The ECON series scales are equipped with a variety of functions to enhance user convenience and cater to diverse applications. Key features include:
Counting Function: This allows users to count similar items placed on the scale. The scale offers six fixed sample sizes: 10, 20, 50, 100, 200, and 500 pieces. To enter the counting mode, place the counted samples on the pan, press the [Func] key until the desired sample size (e.g., "S 10" for 10 pieces) is displayed, and then press the [M] key for confirmation. The scale will then calculate the unit weight and display the number of samples. To recall a previously calculated unit weight, press [Func] until "S Cnt" is displayed, then press [M]. To exit counting mode and return to weighing mode, press [Func] until "S 0" is displayed, then press [M]. If the scale is restarted while in counting mode, it will default to that mode.
Liter Conversion: The scale can convert weight measurements into liters. This function uses a user-programmable conversion factor, with a maximum allowed value of 1.000.
Password Protected Unit Conversion: This feature provides security for unit conversion settings, preventing unauthorized changes.
Weight Accumulation Function: This allows for the accumulation of displayed weights, up to a total of 999,999. When in weighing mode, pressing the [M] key accumulates the current weight. The display will briefly show "[Add xxx]" (where xxx is the number of times weight has been accumulated) and then the accumulated weight, before returning to weighing mode. To view the accumulated weight, press [M] in zero mode (when no weight is on the scale). The display will show "[Add xxx]" and then flash the accumulated weight three times. To clear the accumulated weight, press [ZERO] while the accumulated weight is flashing. The scale will display "[Err-or]" if an attempt is made to accumulate a negative weight. If the accumulated weight exceeds 999,999, the display will show "[tot-of]". If the number of times weight is accumulated exceeds 999, the display will show "[Add-of]".
Selectable Display Speed: Users can choose from five different display update speeds (SPd-1 to SPd-5), with SPd-1 being the fastest and SPd-5 the slowest. This setting can be adjusted in the User Parameter Setting Mode.
Auto Tare: This function automatically tares the weight of a container once it is placed on the scale and becomes stable for 3 seconds. The tare is automatically removed if the scale goes into a negative value.
Peak Hold: This feature displays and holds the maximum weight measured by the scale. Options include:
Auto Sleep: Users can set an auto-sleep time from 01 to 99 minutes. If the scale remains in zero mode for the set time limit, it will enter sleep mode, displaying only the last digit as "0". Setting the sleep time to "00min" disables this function.
Zero Locking Counts: This function allows users to select a zero locking range from 01 to 99 counts, meaning the scale will zero within a specified number of divisions. For example, if 10 is selected and the division is 500mg, the zero locking will be up to 5g.
Stable Time Setting: The scale offers three stable time settings: Stb-1 (Slowest), Stb-2 (Medium), and Stb-3 (Fastest). This allows users to adjust the stability criteria for measurements.
RS-232 Communication Function: This enables the transfer of measuring results to a PC without the need for additional software installation. The scale supports 13 different data formats and three transmission modes (On Pressing COUNT Key, Continuous Transmission, On command "$" from computer). Baud rates of 1200, 2400, 4800, and 9600 are user-selectable. The RS-232 output data can be configured to display Net weight (OUt-N), Gross weight (OUt-G), or Tare weight (OUt-t).
Power ON Zero: This function automatically zeros the weight on the scale during power-on if the weight is less than 20% of the scale's capacity. If the weight exceeds 20%, the scale will display "Err 20" and require a restart. If this function is off, the scale will display the actual weight directly when the weight is greater than 20% of capacity.
The ECON series scales are designed for ease of use with intuitive key operations:
Proper maintenance is crucial for ensuring the accuracy and longevity of the EAGLE ECON series Digital Weighing Scale.
| Units | lb, kg |
|---|---|
| Display | LCD |
| Power | Battery or AC adapter |
| Material | Stainless Steel |
| Warranty | 1 year |