13
Trouble
Check
Solution
The unit doesn’t
operate at all.
Is power fail?
Is plug out?
Is power fuse or switch off?
Is the set time suitable?
Is water full alarm on?
It is normal.
Insert the plug into the
socket steadily.
Change the fuse or switch
on.
Change the set time.
Pour the water.
Cooling/Hating
efficiency is not
good
Is air inlet or outlet blocked?
Is there any other heat
source in room?
Are air filters very dirty?
Is the set temperature
suitable?
Is fan speed set at low?
Clear off the blocks.
Move the heat source.
Clean the air filter.
Change temperature.
Select suitable fan speed.
Too noisy and
vibration
It is the inner liquid
(refrigerant) flowing inside.
Is it inclined?
It is normal.
Place it in a flat place.
The unit starts
and stops
frequently
Is the voltage normal?
Is the exhaust tube fixed
rightly or is it bended?
Have you added extra
exhaust tube
Turn off the unit if the
voltage is abnormal.
Set the exhaust tube
correctly.
Remove the extra tube.
Check code
Diagnosis of malfunction
E2
Room temperature faults
E3
Faulty coil temperature
INSTALLATION ACCESSORIES
Description:
Flexible exhaust hose with adapters ………………1/set
(Φ15cm
Stretch from 36cm up to 150cm)
Window exhaust adapter (flat mouth)………………1pc
Adjustable window slider kit …………………………1/set
From 35 3/8” (90cm) up to 51 1/8” (130cm)
Screw (the length is 3/8”)………………………………1pc
(Only for YPC-07/09/12-S model)
Water cup ……………………………………………1pc
Drain pipe ………………………………………………1pc
2
IMPORTANT SAFEGUARDS
Important Safeguards.
•Read all instructions.
•Disconnect the power plug before dismantling, assembling or before
cleaning.
•Avoid touching mobile parts of the appliance.
•Never insert fingers, pencils or any other objects though the guards whenever
the power plug is connected, especially while running.
•The appliance is not intended for use by young children or infirm persons
unless they have been adequately supervised by a responsible person to
ensure that they can use the unit safely.
•Young children should be supervised to ensure that they do not play with the
appliance.
•Do not use the appliance for any other purpose than its intended use.
•The appliance must not be used if the guards are not fastened according to
instructions.
•When the power cord is damaged, it must be replaced by the manufacturer or
its service agent or a similarly qualified person in order to avoid a hazard.
•Do not use your appliance with an extension cord unless it has been checked
and tested by a qualified electrician or electrical supplier.
•Return to Hagemeyer or authorized service agent.
The air conditioning unit must always be stored and transported upright,
otherwise you may cause irreparable damage to the compressor; in
case of doubt we suggest to wait for at least 24 hours before you start
the air-conditioning unit.
•Avoid restarting the air conditioning unit unless 4 minutes have passed since
being turned off, or the compressor may get damaged.
•Never use the mains plug as a switch to start and turn off the air conditioning
unit. Use the provided ON/OFF switch located on the control panel.
•Always place the portable air conditioner on a dry stable surface.