4 Amended: April 22
EMEA Fire Technical Support: DF6000/CF3000 Applications Guide
Cable Types ................................................................................................................................... 50
Configurations ................................................................................................................................ 50
Ancillary Devices ................................................................................................................................... 54
Detection ........................................................................................................................................ 54
Call points ...................................................................................................................................... 54
Sounders ........................................................................................................................................ 54
Input/output Devices ...................................................................................................................... 54
Zone Monitoring Units .................................................................................................................... 56
Fan Controller FC6/FC18 .............................................................................................................. 56
CFC 301 Technical I/O Unit (Legacy Device) ............................................................................. 56
Smoke Control ............................................................................................................................... 57
MCOM-FC ...................................................................................................................................... 58
4 Way Sounder Control Unit (MPU 424/CSC354CPR) ................................................................. 58
MARDF6 ........................................................................................................................................ 58
Spur Isolator- MSI850 .................................................................................................................... 58
Beam Detector MAB50/100R ........................................................................................................ 58
Repeater Protocol Devices ................................................................................................................... 59
Repeater Panels ............................................................................................................................ 59
LED Repeater & Graphical Mimic Relay Board (CIOP4/8) ............................................................ 60
CIOP7273 ...................................................................................................................................... 62
Touch Screen Repeater ................................................................................................................. 63
Getting Started & Fault Diagnosis ......................................................................................................... 64
Powering the panel. ....................................................................................................................... 64
Panel takes a long time to start the boot up sequence after a watchdog reset (or power up). ..... 64
Power LED not illuminated ............................................................................................................ 64
Power LED on but touch screen is not illuminated ........................................................................ 65
Power LED and touch screen illuminated but no text visible ......................................................... 65
Screen is visible, but touch screen does not respond to touch ..................................................... 65
The touch screen works and is correctly calibrated, but I cannot get to the supervisor entry
screen. ........................................................................................................................................... 65
The general disabled LED is illuminated ....................................................................................... 65
Commissioning ...................................................................................................................................... 66
Loop Checking with a multimeter ................................................................................................... 66
Auto-Learn Function ...................................................................................................................... 66
Problems ............................................................................................................................................... 67
Dual address .................................................................................................................................. 67
The panel goes into fire straight after auto-learn. .......................................................................... 68
The panel constantly resets after auto-learn. ................................................................................ 69
Open circuit Positive/Negative. ...................................................................................................... 69
Short Circuit start or end of a loop. ................................................................................................ 70
Short circuit middle ........................................................................................................................ 71
Fault at address ............................................................................................................................. 71