EasyManua.ls Logo

Eaton Cutler-Hammer PanelMate 3000 Series User Manual

Eaton Cutler-Hammer PanelMate 3000 Series
9 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
PanelMate 3000 Series
PanelMate Power Pro
Cutler-Hammer
EXPRESS SETUPEXPRESS
SETUP
EXPRESS SETUPEXPRESS
SETUP
Question and Answer IconNeed help?

Do you have a question about the Eaton Cutler-Hammer PanelMate 3000 Series and is the answer not in the manual?

Eaton Cutler-Hammer PanelMate 3000 Series Specifications

General IconGeneral
Display TypeLCD
Input Voltage24 VDC
Input MethodTouchscreen
Resolution320 x 240 pixels
Communication PortsRS-232, RS-485
Operating Temperature0°C to 50°C
Storage Temperature-20°C to 70°C
Enclosure RatingNEMA 4X
Memory512 KB RAM

Summary

Installation Procedures

Unpacking and Inspection Procedures

Carefully remove equipment, inspect for shipment damage, and retain cartons for future use.

Hazardous Location Safety

Equipment is suitable for Class I, Division 2, Groups A,B,C,D or non-hazardous areas only.

Parts Checklist

Verifies packing carton contents, including mounting hardware, connectors, and fault relay.

Mounting Guidelines

Unit designed for NEMA 4, 4X, 12 enclosures. Vertical mounting is essential for longevity.

Connectivity Options

DC Power Connection

Unit operates at 24VDC. Use #18 AWG wire. Polarity reversal protection is included.

PC Connectivity

Connect to PC via serial port for firmware and configuration uploads/downloads using provided cable.

Fault Relay Connection

Fault relay can be normally open/closed. It de-energizes on errors, failures, or alarms.

Serial Port Configuration

Serial ports support RS232, RS422, RS485-2. Termination settings are crucial for communication.

Testing and Adjustments

Diagnostic Tests

Perform internal diagnostic tests and display system/configuration information.

Transfer and Run Modes

Use Serial/Network Transfer Mode for data management; Enter Run Mode for PLC communication.

Touchscreen Calibration & Adjustment

Calibrate touchscreen boundaries and adjust display contrast for optimal viewing.

Touchscreen Operation and Maintenance

Touchscreen Functionality

Touchscreen replaces physical controls. Templates are used to arm buttons for interaction.

Touchscreen Cleaning

Use the Cleaning Mode utility for safe cleaning. Avoid solvents and foreign objects.

Touchscreen Calibration Procedure

Calibrate touchscreen in Offline or Run modes by pressing screen indicators sequentially.

Cutout Template and Mounting

Mounting and Torque Specs

Provides cutout dimensions, torque limits for #8-32 studs, and cautions for secure mounting.

Product Specifications

Environmental & Electrical Specs

Covers operating temperature, humidity, NEMA class, altitude, and electrical immunity standards.

Power & Performance Specs

Details voltage, power consumption, current draw, and peak inrush current for unit operation.

Customer Support

Technical Support Contact

Provides contact details for technical assistance, including phone, fax, website, and email.

Related product manuals