2022.10.7
© 2022 Eaton Cummins Automated Transmission Technologies. All rights reserved.
67
TRSM0940 Auxiliary Section Service Procedures | MHP/MXP/VHP/VXP Auxiliary Section Removal and Disassembly
Output Yoke Removal
1. Remove the two bolts that fasten the output Yoke to
the output shaft.
2. Remove the Output Yoke from the Output Shaft. A maul
or hammer may be required to apply force to the yoke
for removal.
Auxiliary Section Removal
1. Remove the 4 9/16” cap screws on the Range Cylinder
Cover.
2. Remove the Range Cover Assembly