3.7 Parameters
To go to Parameters, press & hold “UP & DOWN ARROW” at the same time for
about 5 seconds, within the 8 seconds when you turn the kit on.
P01 : Brightness (1 is the darkest; 3 is the brightest)
P02 : 0 is KM, 1 is MILE
P03 : Voltage grades; 24V/36V/48V/52V/72V
P04 : Sleep time. 0 means the LCD screen will never go off for energy save
mode, other numbers stand for the sleep time (1-60 min).
P05 : PAS grades.
3: 3 level speed for both throttle and PAS
5: 5 level speed for both throttle and PAS
9: 9 level speed for both throttle and PAS
P06: Wheel Size. Unit: inch Precision: 0.1
The wheel size unit shown in inches, must be set correctly.
P07: Range: 1-100
This is 46 for direct drive (1200w and above) motors and 01 for geared (500w -
750W) motors.
P08: Speed Limit
Range: 0-50 km/h, 100 means no limit
The limit is set in Km and can not be switched to a Mil. So calculate it carefully
when you set the limit.
Communication Status (controlled by the controller): The driving speed keeps the
same as the ones we set. Random error: ±1km/h. (Speed limit is for both PAS and
Throttle)
Note: These data are based on KM. When changing KM to Mile, the speed value
on the screen would convert to correct Miles automatically, but if you do not
change the setting of the speed limit from KM to Mile, it would be different from
the real speed limit in Mile.