Min. Water Pressure
bar
0,4
Max. Water Pressure
bar
10
Operation Range
° C
30-65***
Max. Limit temperature
° C
≥ 71
General
Electrical Supply
V AC-Hz
230 VAC-50 Hz
Electrical consumption (HM-HST
model)
Watt
80
130
165
Protection Class
IPX4D
Expansion Vessel
L
8
Weight (Net) (HM-HST)
kg
28,5
30
32
Weight (Net) (HCH)
kg
20,5
22
24
Dimesions (HxWxD)
mm
678x410x288
Flue Lenghts
C13 -Ø60/100 Max.
m
10
C13 - Ø80/125 Max.
m
20
C33 -Ø60/100 Max.
m
10
C33 -Ø80/125 Max.
m
20
Emission Values
CO emission @max capacity (G20)
ppm
<250
<300
CO emission @min capacity (G20)
ppm
<50
C02 ratio (@max-G20)
%
9,5 ± 0,2
C02 ratio (@min-G20)
%
8,9 ± 0,2
C02 ratio (@max-G31)
%
10,6 ± 0,2
C02 ratio (@min-G31)
%
9,9 ± 0,2
Table.7 Technical Table
*It’s recommended to adjust CH temperature set value above 40°C if you don’t use room thermostat.
**It’s not recommended to use DHW flow rate below 2,5 l/min for stable DHW usage.
*/***It depends on maximum inlet temperature value.