Clearance Requirements from Vent Terminations to Building Openings
*All clearance requirements are in accordance with ANSI Z21.10.3a-2017 and the National Fuel Gas Code, ANSI Z223.1
Maintain the following clearances to any
opening in any building:
4’ below, 4’ horizontally from, or 1’ above
any door, operable window, or gravity air
inlet into any building.
3’ above any forced air inlet within 10’.
Vent Clearances When
Heater is Installed Indoors
Illustration
A) A minimum clearance value determined by testing in accordance with Clause 5.20, or;
B) A reference to the following footnote:
“Clearance in accordance with local installation codes and the requirements of the gas supplier.
A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family
dwellings and serves both dwellings.
Permitted only if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the oor.
Notes:
1) In accordance with the current CSA B149.1 Natural Gas and Propane Installation Code
2) In accordance with the current ANSI Z223.1 / NFPA 54 National Fuel Gas Cod
Venting
Termination Clearances
Installation

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Eccotemp i12 Series and is the answer not in the manual?

Eccotemp i12 Series Specifications

General IconGeneral
TypeTankless
Voltage120V
Installation TypeIndoor
Fuel TypeNatural Gas or Propane
Ignition TypeElectronic
Temperature Range80°F to 140°F

Related product manuals