2 Electrical Interface
FT 5000 Control Module
The following sections describe the electrical interface for the FT 5000 Control
Module.
JP1 Connector
Figure 1 and Table 2 show the pinout of the JP1 header connector for the FT
5000 Control Module. The I/O pin function names defined in Table 2 are the
same as those used in the Series 5000 Chip Data Book, which defines the
functions and electrical characteristics for the signals. The I/O signals are
connected directly to the FT 5000 Smart Transceiver without buffering.
MOV_GND
IO2
IO0
CP2_TXLED
SVC-
RST-
FT_NETA
IO10
IO8
IO6
IO4
SCL
SDA_CS1-
IO11
FT_NETB
IO3
IO1
IO5
IO9
IO7
VDD3V3
CP3_RXLED
JP1
HEADER 13X2
2
4
6
8
10
12
14
16
18
20
22
24
26
1
3
5
7
9
11
13
15
17
19
21
23
25
Figure 1. FT 5000 Control Module JP1 Connector
Table 2. FT 5000 Control Module JP1 Connector
Pin Number Signal Name Description
1 GND Ground
2 RST~ Reset (active low)
3 CP3_RXLED RxActive for network activity LED
4 CP2_TXLED TxActive for network activity LED
5 NC No Connect
6 VDD3V3 3.3 V Input Power
7 GND Ground