AC Overcool Max When using the AC to dehumidify,
the section allows you to program how many degrees
below the current set point the Thermostat will run in
order to reach the dehumidify set point.
Aux Heat Settings
Max Outdoor Temperature Allows you to set the
maximum outdoor temperature threshold. Above this
level, the auxiliary heat will not be activated. Instead,
the heat pump will maintain the set point.
Common Heat/Cool Settings
Heat Dierential Temp The minimum dierence
between the current temperature and set temperature
before the system calls for heat. A smaller dierence
means a more comfortable environment, whereas a
larger dierence is more economical.
Heat Dissipation Time The amount of time the fan
will run after the heat set point has been reached and
the call for heat has been turned o. Running the fan
for a period of time allows for any heated air left in the
ducts to circulate throughout the home.
Cool Dierential Temp The minimum dierence
between the current temperature and the set
temperature.
Cool Dissipation Time The amount of time the fan
will run after the cool has been turned o. Running
the fan for a period of time allows for any cooled air left
in the ducts to circulate throughout the home.
Advanced Settings
This section will allow you to customize how long each
stage will run before the next stage will turn on. You may
also program when a particular stage is turned on based
on the temperature delta between the set temperature
and the current temperature.
NEW Reverse staging If this option is enabled, the
thermostat will cycle down from the higher stages so
that as it approaches set point it will only be running
in stage 1. The HVAC equipment will start in stage
1. As the stage 1 temperature delta is exceeded, the
second stage will engage. Once the equipment has
brought the current temperature back to within the
25 Conguring The Smart Thermostat
temperature delta, stage 2 will disengage and stage 1
remain running until the set point is meet.
Stage X Maximum Runtime The maximum amount of
time X stage will run before engaging the next stage.
Options are Auto and 10-120 minutes
Stage X Temperature Delta The minimum dierence
between the current temperature and the set
temperature that will activate this stage (regardless
if the maximum run time of the previous stage was
reached). Options are Auto and 1-10F.
Comp to Aux Runtime The maximum amount of
time this stage will run before engaging the next stage.
Options are Auto and 10-180 minutes
Comp to Aux Temp Delta The minimum dierence
between the current temperature and the set
temperature that will activate this stage (regardless if the
maximum run time of the previous stage was reached).
Options are Auto and 1-10F.
Cool Min On Time Sets the minimum equipment run
time in cool mode.
Heat Min On Time Sets the minimum equipment run
time in heat mode.
Temp Correction
This will allow you to program an oset between what
temperature the Thermostat is measuring versus what
is displayed. If you nd that the temperature where
the Thermostat is located does not represent the room
temperature, this oset allows you to compensate for
that dierence.
Installer Code
This option lets you enable or disable 3262 as the
installer code.
Conguring The Smart Thermostat 26