EasyManua.ls Logo

Ecoflam BLU 500 P AB User Manual

Ecoflam BLU 500 P AB
48 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
LB448
03.10.2005
BLU 500 P AB
BLU 700 P AB
BLU 1000 P AB
BLU 1200 P AB
BLU 1400 P AB
G20-G25
G30-G31
A BRUCIATORI DI GAS AD ARIA SOFFIATA
B BLOWN AIR GAS BURNERS
C BRULEURS GAZ A AIR SOUFFLE
D QUEMADORES DE GAS DE AIRE SOPLADO
Question and Answer IconNeed help?

Do you have a question about the Ecoflam BLU 500 P AB and is the answer not in the manual?

Ecoflam BLU 500 P AB Specifications

General IconGeneral
BrandEcoflam
ModelBLU 500 P AB
CategoryIndoor Fireplace
LanguageEnglish

Summary

OPERATING FEATURES

Max. gas pressure

Maximum gas pressure specifications.

Min. gas pressure

Minimum gas pressure specifications.

Fuel L.C.V.

Fuel Lower Calorific Value.

TECHNICAL DATA

Burner Models

Technical data for BLU 500-700-1000-1200-1400 PAB.

Thermal Power

Maximum and minimum thermal power.

Electrical and Motor Specs

Voltage, motor, and RPM details.

WORKING FIELDS

Output vs. Backpressure

Graphical representation of burner performance.

OVERALL DIMENSIONS

Burner Dimensions

Physical dimensions of the burner in mm.

ELECTRICAL CONNECTIONS

Power supply and wiring

Details on electrical connections and supply.

GAS PIPELINE CONNECTION

Connection and sealing checks

Steps for connecting gas pipeline and verification.

BURNER START-UP PROCEDURE

Pre-start checks

Essential checks before burner start-up.

Start-up sequence

Step-by-step guide for burner ignition.

IMPORTANT ADVICE AND WARNINGS

Installation advice

Key recommendations for installers.

Combustion adjustment guidance

Instructions for optimizing combustion.

Safety and operational warning

Critical safety and operational notes.

CONTROL BOX FUNCTIONS

Landis & Staefa LGB21/LGB22 timing

Description of control box timing functions.

AIR DAMPER MOTOR ADJUSTMENT

SQN 30 151A2700 cam adjustment

Adjusting cams on the air damper motor.

GAS TRAIN INSTALLATION AND SETTING

Gas train setup

Instructions for fitting the gas train.

High flame adjustment

Procedures for setting high flame.

Low flame adjustment

Procedures for setting low flame.

BURNER OUTPUT CALCULATION

Calculate working output

Formula and method for calculating burner output.

COMBUSTION ADJUSTMENT

Combustion adjustment warning

Important note on combustion analysis.

FIRING HEAD SETTING

Adjusting firing head position

Procedure for setting the firing head.

ELECTRODE AND NOSEPIECE

Electrode positioning

Correct positioning of ignition and ionization electrodes.

Nosepiece removal

Steps for removing the burner nosepiece.

GAS TYPE CONVERSION

BLU 500 gas conversion

Changing burner operation from Natural Gas to LPG.

BLU 700-1000 PAB gas conversion

Switching gas types for BLU 700-1000.

GAS TYPE DISK POSITIONING

Disk positioning for gas types

Correct disk placement for Natural Gas and LPG.

PRESSURE SWITCH ADJUSTMENTS

Gas minimum pressure switch

Procedure for adjusting gas pressure switch.

Air pressure switch adjustment

Procedure for adjusting air pressure switch.

FLAME DETECTION AND CONTROL PANEL

Flame detection system check

Method for checking flame detection.

Control panel component description

Explanation of control panel elements.

MAINTENANCE AND TROUBLESHOOTING

Yearly maintenance schedule

Recommended annual checks.

Pre-intervention checks

Checklist before starting work.

Short troubleshooting guide

Common problems and their solutions.

Related product manuals