4
www.ecoflam-burners.com
EN
420010518600
Technical data MAX 1
Burner output
max/min kW - kcal/h
41,4 17,6
35604 15136
Oil throughput
max/min kg/h
3,5 1,5
Hydraulic system
1 stage
1
Regulating ratio 1:1
Fuel oil
Light oil (L.C.V. 10.200 kcal/kg max. visc 1,6÷6 mm
2
/s at 20°C)
(EL) Hu = 11,86 kWh/kg
Emission class Standard Class 2 - OIL EN267 (NOx < 185 mg/kWh)
Control box ARISTON E-BCU OIL
Air regulation
Air flap
-
Flame monitor sensor
Ignition transformer danfoss / cofi
Fuel-oil pump danfoss / suntec
Electric motor
rpm - watt
2800 (3400) rpm
75 W
Voltage 230 V / 50 (60) Hz
Power consumption
(operation)
300 W
Weight 7 kg
Protection level IP40
Sound pressure
level dB(A)
60
Ambient temp. for storage -20°…+70° C
Temperature
for use
-10°…+60° C
Overview - Technical data