Saving the adjustment values in the display.
If the burner setting procedure has been successfully completed, the servomotor
positions for all the operating states will be fixed in the control unit. It is possible to store
a backup copy of the values in the display.
To do this, press the button , the screen opposite is displayed. Using the button
select the menu "Save adjustment values" and confirm with the button .
The screen opposite appears. Place the cursor on the symbol , press the button
to begin loading the adjustment values from the control unit to the display.
A this point, it is possible to:
- store the values in the display; to do this place the cursor on the symbol and confirm
with button .
- quit the menu without storing the data, with the symbol .
Start up
- Saving the adjustment values in the display