EasyManua.ls Logo

Ecoflo Coco Filter EC7 Series - Dosing Volume Adjustment

Ecoflo Coco Filter EC7 Series
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Premier Tech Aqua 28/32 Polyethylene Ecoflo
®
Coco Filter Installation Guide CAN/USA
339975 Rev. 5.0
6.10 Dose adjustment
You may need to adjust the dosing volume. In order to adjust the dosing volume, you may need to adjust the float
position.
Floats factory settings are set to provide 25 to 40 gallons per dose depending on model’s capacities. However,
floats can be adjusted on site according to information provided in table below if bigger dose is required depending
on specific site conditions and design. For pump to gravity distribution we recommend, theoretically, a dose volume
of ¼ of daily design flow, 4 times a day.
Table 7 Ajustable Dosing Volume
Models
2.8
3.4
4.1
5.7
7.3
Float Adjustment
Factory Settings
25 US Gal
(95 L)
30 US Gal
(110 L)
35 US Gal
(130 L)
30 US Gal
(110 L)
40 US Gal
(150 L)
Cut 1”
80 US Gal
(300 L)
95 US Gal
(360 L)
100 US Gal
(375 L)
85 US Gal
(320 L)
115 US Gal
(435 L)
Cut 2”
105 US Gal
(400 L)
120 US Gal
(450 L)
130 US Gal
(490 L)
110 US Gal
(415 L)
155 US Gal
(585 L)
Cut 3
130 US Gal
(490 L)
150 US Gal
(560 L)
135 US Gal
(510 L)
140 US Gal
(530 L)
195 US Gal
(740 L)
Cut 4
160 US Gal
(600 L)
180 US Gal
(680 L)
200 US Gal
(750 L)
175 US Gal
(660 L)
235 US Gal
(890 L)
Float tree adjustment for Ecoflo
®
Coco Filter (example model 3.4 PACK)
For more information consult
ptzone.premiertechaqua.com