8
EN
Troubleshooting
Indicator Problem Solution
Flashing
High temperature charging
protection
Charging can be resumed
automatically after the battery cools
down
Flashing
High temperature
discharging protection
The power supply can be resumed
automatically after the battery cools
down
Flashing
Low temperature charging
protection
Charging can be resumed
automatically after battery
temperature rises above 0°C
Flashing
Low temperature
discharging protection
The power supply can be resumed
automatically after the battery
temperature rises above -12°C
Flashing
Battery overload protection,
short circuit protection
during discharging
Remove overload appliances
Solid Battery failure Contact the after-sales service
RECHARGING TIME
RECHARGING TIME
If a warning sign shows up on the LCD screen during use and does not disappear
after a restart, please stop using it immediately (do not try to charge or discharge). If
you look for more assistance, please contact EcoFlow customer service.