TROUBLESHOOTING
Details of Error Icons Error Type Recovery Methods
Battery discharge low
temperature protection
Normal operation will resume auto-
matically when the battery warms up.
Battery discharge high
temperature protection
Normal operation will resume auto-
matically after the battery coolsdown.
Battery charging low
temperature protection
Normal operation will resume auto-
matically after the battery temperature
is restored to above 3°C (37.4°F).
Battery charging high
temperature protection
Normal operation will resume auto-
matically after the battery coolsdown.
AC output low-tem-
perature protection
Normal operation will resume auto-
matically after the ambient tempera-
ture is restored.
AC output over-tem-
perature protection
outlet of the product are unobstructed.
Normal operation will resume auto-
matically once the cause is eliminated
and the temperature decreases.
USB-C or car charging
overload protection
Normal operation will resume after
removing the over-powered device and
restarting the machine.
AC output overload
protection
Normal operation will resume after
removing the over-powered device and
restarting the machine. Electrical ap-
pliances must be used within the rated
power (for the power limit of electri-
cal appliances in the X-Boost mode,
please refer to the X-Boost function
introduction)
Charging overload
protection
Remove the charger and normal oper-
ation will resume automatically after
being restarted.
Fan blocking
Please check whether the fan is
blocked by foreign objects and remove
the cause of the error.
Failure of communi-
cation between main
control board and AC
Normal operation will resume auto-
matically after being restarted.
If any alert occurs during the use of this product and the alert icon does not
disappear after the product is restarted, please stop using the product immediately
(do not attempt to charge or discharge).
If the above information fails to resolve your problem, please contact customer ser
vice
for further support.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the EcoFlow RIVER 2 Max and is the answer not in the manual?

EcoFlow RIVER 2 Max Specifications

General IconGeneral
WaveformPure sine
Input voltage220-240 V
Apps supportedYes
Charging sourceAC, Cigar lighter, Solar, USB
Battery capacity- mAh
Solar panel power220 W
Battery technologyLithium Iron Phosphate (LiFePO4)
Solar panel current13000 mA
Solar panel voltage11 - 50 V
USB Type-A output power12 W
USB Power Delivery up to100 W
Number of charging cycles3000
Number of simultaneously connected devices (max)-
ShapeRectangle
Control typeButtons
Product colorBlack, Grey
USB connector typeUSB Type-A, USB Type-C
AC outlets quantity2 AC outlet(s)
USB Type-A output ports3
Quantity per pack1 pc(s)
Cables includedAC, Cigar lighter
Storage temperature (T-T)-10 - 45 °C
Operating temperature (T-T)20 - 30 °C
Weight and Dimensions IconWeight and Dimensions
Depth260 mm
Width270 mm
Height196 mm
Weight6000 g