Auto-Defrost Function
Auto Shut-Off
When the water tank is full or the water tank is not installed properly, the
unit will shut off automatically and “U” will appear on the display.
After emptying the tank or installing the water tank properly, the unit will
return to the previously set mode.
Memory Function
If the ambient temperature is too low, the dehumidier switches to de-
frost mode. The compressor switches off and the unit runs with the fan
motor switched on until the frost has disappeared. “F” is shown on the
display. Manual intervention is not possible during defrost mode.
In case of power failure the unit will return to the previously set mode as
soon as power is recovered.