Adjust Dispensing: Conveyor Timed
Adjust Detergent
Adjust Rinse Aid
Adjust Third Product
Set length of detergent dispense:
Range: 1-30 seconds, interval of 0.1 seconds
Default: 2.5 seconds
Adjust Detergent Valve Run Time
Adjust Detergent Dose Interval
Adjust Initial Detergent Charge
Set frequency of detergent dosing:
Range: 1-10 racks, interval of 1 rack
Default: 1 rack
Adjust Detergent Valve Run Time
Adjust Detergent Dose Interval
Adjust Initial Detergent Charge
Set the initial detergent charge after machine fill Range.
1-999 seconds. Interval 37 sec.
Adjust Detergent Valve Run Time
Adjust Detergent Dose Interval
Adjust Initial Detergent Charge
1
Adjust Detergent
Adjust Rinse Aid
Adjust Third Product
Back
Set rinse pump speed:
Range: 8-30RPM, increments of 0.5RPM
Default: 15RPM
Prime the rinse line for 30 seconds at the programmed Rinse
Pump Speed.
Adjust Rinse Pump Speed
Rinse Pump Prime
Adjust Rinse Pump Speed
Rinse Pump Prime
01
Adjust Detergent
Adjust Rinse Aid
Adjust Third Product
Back
Set third product rinse speed:
Range: 8-30RPM, increments of 0.5RPM
Default: 15RPM
1
Adjust Detergent
Adjust Rinse Aid
Adjust Third Product
Back
Adjust Third Product Pump Speed
Logout
View Information
Adjust Dispensing
Diagnostics & Troubleshooting
Setup System
2.5 Seconds
1 Racks
37 Seconds
15.0 RPM
Press start to begin priming
15.0 RPM