417102233 Betriebsanleitung EMP III E00, E10
11 Technical Specifications
11.1 Pump keys
11.1.1 Pump key 1
E 00 = Terminal box on motor,
mechanical stroke adjustment
on/off switch, mechanical stroke adjustment
2. Pump output 50 Hz (60 Hz)
00250 = 25 l/h (30 l/h)
00540 = 54 l/h (64 l/h)
00800 = 80 l/h (96 l/h)
01200 = 120 l/h (144 l/h)
spezial version: high pressure
00160 vs. 1,6 MPa (16 bar) = 14,7 l/h (21,2 l/h)
00250 vs. 1,2 MPa (12 bar) = 23,5 l/h (28,2 l/h)
PP = PP (standard)
PV = PVDF
4. Metering backpressure (not freely selectable)
03 = 0,3 MPa (3 bar) (for 120 l/h) (0,25 MPa)
04 = 0,4 MPa (4 bar) (for 80 l/h) (0,32 MPa)
10 = 1 MPa (10 bar) (0,8 MPa)
spezial version: high pressure
12 = 1,2 MPa (12 bar) (0,96 MPa)
16 = 1,6 MPa (16 bar) (1,28 MPa)
FP = Viton B (standard)
EP = EPDM
VA = stainlesssteel
PV = PVDF
08 = suction valve without spring; pressure valve
double spring loaded (each 0,02 MPa)
10 = suction valve without spring; pressure valve
spring loaded (0,01 MPa)
99 = without spring (standard)
01 = mains power cable 2 m (standard)
02 = 3-core m. power cable 2.4 m cable end sleeves
09 = mains power cable, US version
13 = mains power cable, Italian version
99 = without mains power cable
02 = 115V / 60 Hz
03 = 230V / 50 Hz (standard)
04 = 230V / 60 Hz
10 = 3PE 400/230 V 50/60 Hz (only version E00)