ELECTRICAL POWER CONNECTION: Electrical and grounding connections must comply with the applicable portions of the
National Electrical Code ANSI/NFPA 70 (latest edition) and/or other electrical codes.
Disconnect electrical power supply and lockout the disconnect switch to indicate that you are working on the circuit.
The dishmachine data plate is located on the right side front of the machine. Refer to the data plate machine voltage, total
amperage load and serial number.
To install the incoming power lines, open the lower control box by removing the
control box lid. Install 3/4” conduit into the pre-punched holes in the back of the
control box. Route power wires and connect to power block and grounding lug.
Install the service wires (L1, L2 & L3 (Where applicable)) to the appropriate ter-
minals as they are marked on the terminal block. Install the grounding wire into
the lug provided.
It is recommended that “DE-OX” or another similar anti-oxidation agent be used
on all power connections.
VOLTAGE CHECK: Apply power to the dishmachine. Note: Do not turn the
machine on. Check the incoming power at the terminal block and ensure it cor-
responds to the voltage listed on the data plate. If not, contact a qualified service
agency to examine the problem. Do not run the dishmachine if the voltage is too
high or low. Shut off the service breaker and mark it as being for the dishmachine.
Advise all personnel of any problems and of the location of the service breaker.
Replace the control box cover and tighten the screws.
ES-2000HT INTL Installation & Operation Manual 7610-003-24-90
Issued: 07-10-2006 Revised: N/A
SECTION 2: INSTALLATION/OPERATION INSTRUCTIONS
ELECTRICAL INSTALLATION INSTRUCTIONS
7
Incoming Power Connection
Power BlockGround Lug