Installation
and
Operating
Instructions
ftl
D
l
Vertical
and
Horizontal
Forced
Air/tlydronic
GV/GH
36
Thru
67 Series
E-"
v
E]
Fr
-
6
-
t
A
-
e)
I
tr
-
)
A
V
a
A
v
()
(,
#.
FT"T
Question and Answer IconNeed help?

Do you have a question about the Econar GeoSource DualTEK GV591 and is the answer not in the manual?

Summary

IV. HYDRONIC SIDE HEAT EXCHANGERS

A. Radiant Floor Heating

Details on using radiant floor tubing with the heat pump, including comfort and efficiency.

V. APPLICATIONS OF HYDRONIC SIDE HEAT EXCHANGERS

A. Storage Tanks

Explains the use of water storage tanks with the heat pump for better system performance and efficiency.

VI. EARTH LOOP WATER PIPING

A. Closed Loop Applications

Covers closed loop systems, pipe types, sizing, and antifreeze requirements for earth loops.

B. Open Loop Applications

Discusses open loop systems, well water requirements, and system components.

VIII. UNIT SIZING

IX. ELECTRICAL SERVICE

X. 24 VOLT CONTROL CIRCUIT

5. Compressor Lockouts

Causes and indications of compressor lockouts and how to reset them.

XI. STARTUP

XIV. TROUBLESHOOTING GUIDE FOR UNIT OPERATION

Entire unit does not run.

Troubleshooting steps for when the entire unit fails to operate.

Blower motor runs but does not, or compressor short cycles.

Diagnosing issues with the blower motor or compressor cycling.

Refrigerant Charge

Diagnosing and correcting issues related to refrigerant levels and charge.

Compressor

Troubleshooting compressor-related problems, including performance and failure.

Blower Motor Defective

Diagnosing a defective blower motor and its potential causes.

Unit will not operate on heating

Steps to take when the unit fails to provide heat.

Unit does not cool

Troubleshooting steps for when the unit fails to provide cooling.

Evaporator (air coil) ices over

Identifying causes and solutions for evaporator icing.

XV. TROUBLESHOOTING GUIDE FOR LOCKOUT CONDITIONS

Heating - High Pressure (Head) (Condenser;Air Side)

Causes for high pressure lockouts in heating mode related to airflow or temperature.

Heating - Low Pressure (Suction) (Evaporator;Earth Coupled Side)

Causes for low pressure lockouts in heating mode related to earth loop flow or temperature.

Cooling - High Pressure (Head) (Condenser;Earth Coupled Side)

Causes for high pressure lockouts in cooling mode related to earth loop flow or temperature.

Cooling - Low Pressure (Suction) (Evaporator;Air Side)

Causes for low pressure lockouts in cooling mode related to airflow or temperature.

Econar GeoSource DualTEK GV591 Specifications

General IconGeneral
BrandEconar
ModelGeoSource DualTEK GV591
CategoryHeat Pump
LanguageEnglish