EcoSource Low Voltage Installation
Table 3: J5 Connector Pinout
Pin Wire Color Label on Backplate Function
1 OR GND
Thermostat Signal Ground (not
an earth ground)
2 BR +10V 10 Volts DC Output
3 RD NTC Probe 1 Temperature Probe 1
4 RD NTC Probe 1 Temperature Probe 2
5 * WH 0-10v/4-20mA out 1
Analog Output #1 (VO model
only)
6 * BK 0-10v/4-20mA out 2
Analog Output #2 (VO model
only)
7 BR CT Input 1
Current Transformer Input for
Amperage
8 YL CT Input 1
Current Transformer Input for
Amperage
9 † BK CT input 2
Current Transformer Input for
Amperage
10 † GR
CT input 2 Current Transformer Input for
Amperage
11 † BL
CT input 3
Current Transformer Input for
Amperage
12 † OR
CT input 3 Current Transformer Input for
Amperage