Instruction Manual
MP40w
Protecting your VorTech
Protect the pump from water
The VorTech’s motor housing and
driver are NOT WATERPROOF. Any
water allowed into these components
can damage them enough to require
replacement. This kind of damage is
NOT covered in the VorTech’s warranty.
Protect these components from splashes
of any kind.
Maintenance
Wear of the drive shaft
The VorTech pump features a wear
component in the form of the drive shaft.
This part is designed with a special
engineering grade plastic which extends
the part’s lifetime. The plastic drive
shaft can be expected to last for years,
depending on the speed, frequency, and
alignment of the pump.
The wet magnet and drive shaft should
be observed periodically to monitor
wear. If the magnet begins to how signs
of rapid oxidation in the form of bubbles
on the magnet surface, they may need
to be replaced. Replacements can be
purchased directly from EcoTech Marine.
Cleaning your VorTech
The VorTech may need thorough cleaning
of the components periodically to
keep it running optimally. This can be
accomplished by disassembling the wet
half of the pump and gently brushing
the components with a soft brush under
running water. Soaking these parts in
a mild acid solution such as vinegar
may be necessary if there is an extreme
amount of calcium buildup. Do not use
strong acids as this may damage the
components.
Troubleshooting
Break-in
The VorTech pump is engineered to adapt
to its aqueous environment. During the first
week of use, your pump may run noisier or
stall. The noise should quiet dramatically over
night and any stall conditions can safely be
reset by manually cycling the power to your
pump.
Driver Error Codes
Over Temperature Condition
In the event of a motor overheating, the
pump will automatically shut down for a
period to allow for cooling. Once the motor
has cooled, the driver will automatically
restart and resume normal operation. You
may experience an overheating error from a
misalignment.
Stall Condition
In the event of a motor stall, the pump may
have stopped for a few possible reasons. You
should first check that there is not something
blocking the propeller from spinning. Next,
check to make sure the magnets are not
rubbing on either the pin spacer or the frame
cover.
Miscellaneous Error
This error could be attributed to a
communication error between pumps or an
unidentified error in the wave driver.
FCC Warnings:
Operation is subject to the following two
conditions: (1) this device may not cause
interference, and (2) this device must accept
any interference including interference that
may cause undesired operation of the device.
Changes or modifications not expressly
approved by EcoTech Marine could void
the user’s authority to operate the VorTech
Wireless Wave Driver.
Customer Support
service@ecotechmarine.com
(610) 954-8480
OR visit our forum at www.ReefCentral.com
Sales inquiries please contact:
sales@ecotechmarine.com
(800) 785-0338
ErrorCodes:
Stall
Over Temp
Stall
Condition
Over
Temp
Condition
MiscError
Normal Oxidized
Question and Answer IconNeed help?

Do you have a question about the Ecotech Marine VorTech MP40w and is the answer not in the manual?

Ecotech Marine VorTech MP40w Specifications

General IconGeneral
BrandEcotech Marine
ModelVorTech MP40w
CategoryWater Pump
LanguageEnglish

Summary

VorTech Pump Protection and Maintenance

Protecting the Pump from Water

Motor housing and driver are not waterproof; water damage is not covered by warranty. Protect from splashes.

Drive Shaft Wear and Maintenance

Drive shaft is a wear component made of engineering plastic for extended life. Monitor for oxidation.

VorTech Cleaning Procedures

Periodic cleaning of wet half components with a soft brush or mild acid solution like vinegar.

VorTech Troubleshooting and Errors

Pump Break-in Period

Pump may run noisier or stall during the first week; reset by cycling power.

Over Temperature Condition

Motor shuts down for cooling; driver restarts automatically. Caused by overheating or misalignment.

Stall Condition

Pump stops due to blockage or magnets rubbing on pin spacer/frame cover.

Miscellaneous Error

Attributed to communication error between pumps or unidentified error in wave driver.

VorTech Pump Installation

Specifications and Operating Parameters

Lists flow rate, power consumption, maximum motor temperature, and aquarium wall thickness.

Preparation and Placement

Clean aquarium surface before installation. Place pump away from corals and sensitive areas.

Adjusting the Pin Spacer

Ensures proper gap for aquarium wall thickness. Crucial for correct mounting and to avoid damage.

Programming Multiple VorTech Pumps

Slave Modes: Sync and Anti-Sync

Configure slave pumps to replicate (Sync) or inversely replicate (Anti-Sync) the master pump.

Pump Group Configuration Steps

Steps to clear memory, enter configuration mode, assign master/slaves, and cycle power for pump groups.

VorTech Wireless Wave Driver Modes

General Operational Modes

Details Constant Speed, Reef-Crest Random, and Lagoonal Random modes for pump operation.

Pulse Mode Operation

Allows setting maximum speed and adjusting pulsing frequency via the dial.

Feed Mode and Battery Backup

Feed Mode pauses pumps for 10 minutes. Battery Backup mode activates during power outages.

VorTech Mounting and Safety

General Safety Warnings

Powerful magnets can cause injury. Avoid sensitive electronics. Motors/drivers can be hot. Never run dry.

Attaching the VorTech

Steps to attach motor assembly and propeller housing using gaskets and mounting tabs.

Protecting the Pump From Falling

Use cord mounting tab to prevent damage if the pump dislodges from the aquarium glass.

Aligning the VorTech Pump

Adjust pump housing slightly to eliminate vibration and noise for optimal performance.