OFF OFF OFF
PRELOAD BLACK OUT BLACK OUT
IGNITION BLACK OUT BLACK OUT
START START STANDY-BY THEN REIGNITION
OPERATION OPERATION STANDY-BY THEN REIGNITION
FINAL CLEANING FINAL CLEANING FINAL CLEANING
STAND-BY STAND-BY STAND-BY
ALLARM ALLARM ALLARM
ALARM MEMORY ALARM MEMORY ALARM MEMORY
• Excessive pellet load in combustion chamber
• Stove/chimney ue dirty
(occurs in the event of a board malfunction)
• Failure check carried out by technician
• replace the circuit board
(occurs when the circuit board does not read the smoke extractor revs; call CAT)
• Smoke extractor blocked
• Speed sensor not working
• Smoke extractor not working
• Smoke motor thermostat intervention
• No earth connection
• faulty circuit board
(occurs when the water temperature into the boiler is over 90°C)
- Check the hydraulic circuit
- Check for air into the circuit
- Check circuit valves/taps
- Check stove cleaning
- Check exhaust outlet
- Seek Technical Assistance