- 22 -
ENGLISH

The answers are listed below in summary form, for further details see the other pages of this document.

Smoke outlet that is at least 80 mm in diameter.
An air inlet in the room that is at least 80 cm².
¾” G outlet and inlet tting.
¾” G drains connection for overpressure valve.
¾” G load tting.
A certied electrical connection with a thermal magnetothermic switch 230V +/- 10% 50 Hz.
(assess the division of primary and secondary circuits).

NO. Using the boiler-stove without water will damage it.

NO. Most of the heat is transferred to the water.
Emit a small amount in the installation environment in the form of radiation from the glass hearth. It is advisable in any case to
use a radiator in the same room.

NO, just like other boilers, it must be connected to a collector from which the water is then distributed to the radiators.

It is possible to produce hot sanitary water evaluating the power of the stove and the water plant.

NO, a discharge which is conform with standards (UNI 10683/05) must reach the ridge of the roof, and in any case proper fun-
ctioning requires a vertical stroke of at least 1.5 meters; avoiding that in case of power outage or wind, a slight amount of smoke
forms in the installation environment.

Yes, to replenish the air used by the boiler-stove for combustion. The smoke extractor draws the air from the room into the com-
bustion chamber.

The desired water temperature or that of the room; the boiler-stove will then adjust the power accordingly to obtain or maintain
this.
For small systems, a mode can be set that ignites and shuts down the boiler-stove accordingly, as the water temperature is reached.
(contact DEALER for initial start up)

Before you ignite the boiler-stove, every time, when it is off and cold. AFTER HAVING BRUSHED THE EXCHANGER PIPES
and moved the smoke duct cleaning rods (see page 18).

Yes, at least once a month when the boiler-stove is not used for some time.

NO. The boiler-stove has been designed to burn wood pellets that are 6 mm in diameter. Any other material can damage it.