Rated power 11,3 kW
Water heating power 10 kW
Approx. overall efciency 90,1 %
Approx. water efciency 86,1 %
CO emission (13% O2) 190 ppm
Max. pressure 2 bar
Operating pressure 1,5 bar
Smoke output temperature from test EN14785 113 °C
Minimum draught 12 Pa
Min./max. autonomy 10 / 33 ore
Fuel consumption min./max. 0,8 / 2,7 kg/h
Hopper capacity 27 kg
Heating capacity * 295 m³
Weight including packing (steel/ceramic) 184/197 kg
Diameter of smoke extract duct male thread 80 mm
Air intake duct diameter (male) 40 mm
546
992
552
Assieme generale
SCALA
DISEGNO
ESP. DATA MODIFICA
CODICE TAGLIO:
CODICE LAVORATO:
da 1 a 30
LAVORAZIONI MECCANICHE
NOME PRODOTTO
DESCRIZIONE PARTICOLARE
da 30 a 100
TRATTAMENTI PROTETTIVI
Visto disegno
Visto controllo
da 0 a 200
oltre 200
angolo
FUSIONI - STAMPATI PIEGATURE
oltre 100
angoli
da 1 a 6
da 6 a 30
da 30 a 100
oltre 100
TOLLERANZE
GENERALI
2229.000
1:20
GRUPPO DI APPARTENENZA
peso
00 17/05/2011 PRIMA EMISSIONE
Pref.
± 0.25
± 0.4
± 1°
± 2%
± 0.8
± 0.5
± 0.2
± 30'
± 0.1
± 0.4
± 0.6
± 0.2
-
M.S.
FLEXA - 2229
.
546
992
552
Assieme generale
SCALA
DISEGNO
ESP. DATA MODIFICA
CODICE TAGLIO:
CODICE LAVORATO:
da 1 a 30
LAVORAZIONI MECCANICHE
NOME PRODOTTO
DESCRIZIONE PARTICOLARE
da 30 a 100
TRATTAMENTI PROTETTIVI
Visto disegno
Visto controllo
da 0 a 200
oltre 200
angolo
FUSIONI - STAMPATI PIEGATURE
oltre 100
angoli
da 1 a 6
da 6 a 30
da 30 a 100
oltre 100
TOLLERANZE
GENERALI
2229.000
1:20
GRUPPO DI APPARTENENZA
peso
00 17/05/2011 PRIMA EMISSIONE
Pref.
± 0.25
± 0.4
± 1°
± 2%
± 0.8
± 0.5
± 0.2
± 30'
± 0.1
± 0.4
± 0.6
± 0.2
-
M.S.
FLEXA - 2229
.
546
992
552
Assieme generale
SCALA
DISEGNO
ESP. DATA MODIFICA
CODICE TAGLIO:
CODICE LAVORATO:
da 1 a 30
LAVORAZIONI MECCANICHE
NOME PRODOTTO
DESCRIZIONE PARTICOLARE
da 30 a 100
TRATTAMENTI PROTETTIVI
Visto disegno
Visto controllo
da 0 a 200
oltre 200
angolo
FUSIONI - STAMPATI PIEGATURE
oltre 100
angoli
da 1 a 6
da 6 a 30
da 30 a 100
oltre 100
TOLLERANZE
GENERALI
2229.000
1:20
GRUPPO DI APPARTENENZA
peso
00 17/05/2011 PRIMA EMISSIONE
Pref.
± 0.25
± 0.4
± 1°
± 2%
± 0.8
± 0.5
± 0.2
± 30'
± 0.1
± 0.4
± 0.6
± 0.2
-
M.S.
FLEXA - 2229
.
99
55
54,5
* two fuses are inserted
on the socket behind
the boiler-stove, tted
with a switch one is
functional and the other
is spare.
*
*
* The heatable room dimensions are calculated on the basis of
pellets with an lhv of at least 4300 kcal/kg and home insulation
in compliance with Italian law 10/91, and subsequent changes
together with an expected heat output of 33 Kcal/m³ per hour.
* It is also important to consider the position of the boiler-stove
in the room to be heated.
Power supply 230Vac +/- 10% 50 Hz
On/off switch yes
Average power consumption 150 W
Power consumption during ignition 400 W
Remote control frequency infrared
Protection on mains power supply** Fuse F4 AL, 250
Protection on electronic circuit board Fuse F4 AL, 250
32,3
2,8
4
14
23,7
35,5
13
9
8
3
4,5
16,7
safety valve ½”
outlet ¾”
inlet ¾”
top-up ½”
boiler drain
cock
Combustion
air Ø 40 mm
Smoke outlet
Ø 80 mm
Taken serial
Rs232