[root@localhost template]# make install
IV-3-2. Usage
1. To load the driver manually, go to the driver directory and execute the
following commands:
[root@localhost template]# modprobe usbnet
[root@localhost template]# insmod ax88179_178a.ko
2. To unload the driver, execute the following command:
[root@localhost anywhere]# rmmod axax88179_178a
IV-3-3. Driver Parameters
The following parameters can be set when using insmod:
Msg_enable=0xNNNNNNN
Specifies the msg_enable of usbnet.
Example:
Insmod ax88179_178.ko msg_enable=0x00000000
bszie=xx
Specifies the Rx Bulk In Queue size (KB)
If bszie value is between 1 and 5, the bszie value is fixed at 5KB.
If bszie value is over 24, the bszie value is fixed at 24KB.
If bszie value equals zero, the Bulk In Queue function is
disabled.