© 2019 United Technologies Corporation 1 / 5 P/N 3102545-EN • REV 002 • ISS 24JUN19
Genesis GC Series Signaling
Appliance Installation Sheet
Description
Genesis GC Series horns, strobes, and horn-strobes are ceiling- or
wall-mounted plug-in fire alarm signaling appliances designed for
indoor dry applications. See Table 1 through Table 3 for a list of
models.
Table 1: Horn models
Number
Description
GCARF
Ceiling horn, red, FIRE
GCARF
-FR Ceiling horn, red, FEU
GCARF
-SP Ceiling horn, red, FUEGO
GCARN
Ceiling horn, red, no marking
GCAWF
Ceiling horn, white, FIRE
GCAWF
-FR Ceiling horn, white, FEU
GCAWF
-SP Ceiling horn, white, FUEGO
GCAWN
Ceiling horn, white, no marking
Table 2: Strobe models
Number
Description
GCVRF
Ceiling strobe, red, FIRE
GCVRF
-FR Ceiling strobe, red, FEU
GCVRF
-SP Ceiling strobe, red, FUEGO
GCVRN
Ceiling strobe, red, no marking
GCVWF
Ceiling strobe, white, FIRE
GCVWF
-FR Ceiling strobe, white, FEU
GCVWF
-SP Ceiling strobe, white, FUEGO
GCVWN
Ceiling strobe, white, no marking
Table 3: Horn-strobe models
Number
Description
GCAVRF
Ceiling horn-strobe, red, FIRE
GCAVRF
-FR Ceiling horn-strobe, red, FEU
GCAVRF
-SP Ceiling horn-strobe, red, FUEGO
GCAVRN
Ceiling horn-strobe, red, no marking
GCAVWF
Ceiling horn-strobe, white, FIRE
GCAVWF
-FR Ceiling horn-strobe, white, FEU
GCAVWF
-SP Ceiling horn-strobe, white, FUEGO
GCAVWN
Ceiling horn-strobe, white, no marking
Genesis GC Series signaling appliances feature:
Field-configurable horn and strobe outputs. See Figure 2.
Enhanced synchronization circuitry to comply with the latest
requirements of UL 1638 and CAN/ULC-S526.
Input wiring test points on the front of the appliance when the
cover is removed.
Note: Synchronized operation requires a separately installed
synchronization device. See the control unit or remote booster/auxiliary
power supply compatibility list for compatible synchronization devices.
Configuration
Caution: Equipment damage hazard. Using excessive force when
removing the appliance cover may damage the cover and prevent it
from latching in place.
To configure the signaling appliance:
1. Remove the appliance cover. See Figure 1.
Insert a small, flat-bladed screwdriver into the slot at the bottom of
the appliance.
Gently pull up on the screwdriver to pry the bottom of the
appliance cover down and away from the appliance.
Lift the bottom of the cover out and over the top of the appliance.
2. Set the light and sound output switches. See Figure 2.
3. Replace the appliance cover.