Vigilance II Monitor
Quick Reference Guide
Set Time/Date
Full/Split
Screen Icon
• STAT Boxes
Data Relationship
Plot
• Diagnostic Plot
Home Icon
Return to Home
Conguration
Help Icon
Access Help
Screens
Alarm/Alert Help
Setup Icon
Display Preferences
Cable Test
Language Selection
Serial/Analog Port Setup
Patient
CCO Cable
Connector
SvO
2
/ScvO
2
Connector
Cable Test
Ports
On/Off
Press to Activate Monitor
CCO
Start/Stop
Bolus Mode
Patient Data
• Cardiac Prole
Oxygenation Prole
Trend Scroll
Alarm Silence, 2 min
Navigation Knob
Rotate to Navigate,
Push to Select
Question and Answer IconNeed help?

Do you have a question about the Edwards Vigilance II and is the answer not in the manual?

Edwards Vigilance II Specifications

General IconGeneral
ManufacturerEdwards Lifesciences
ModelVigilance II
DisplayLCD screen
Power SupplyAC power supply
ApplicationsContinuous cardiac output and hemodynamic monitoring
TechnologyThermodilution
Parameters MeasuredCardiac output, oxygen delivery

Summary

Monitor Interface Controls

Power and CCO Controls

Controls for powering the monitor on/off and starting/stopping CCO monitoring.

Data Display and Navigation

Features for viewing patient data, trends, and navigating the monitor interface.

Alarm and Help Functions

Functions for silencing alarms and accessing help screens.

Monitor Navigation and Setup

Time and Screen Configuration

Setting the time/date and managing screen layouts like Full/Split.

System Setup and Access

Icons for accessing system setup, home configuration, and help.

Monitor Connectors

Patient Cable Connectors

Connectors for patient CCO and SvO2/ScvO2 cables.

Diagnostic Ports

Ports used for cable testing and other diagnostic functions.

Oximetry Setup and Calibration

In-Vitro Calibration Process

Steps for calibrating the oximetry module using lab values before patient use.

In-Vivo Calibration Steps

Procedure for calibrating oximetry directly on the patient.

Transporting the Monitor

Guidance on how to transport the Vigilance II monitor with the patient.

Continuous Cardiac Output Monitoring

CCO Cable Connection

Connecting the patient CCO cable and required ECG interface cable.

Starting and Configuring CCO

Initiating continuous cardiac output monitoring and setting parameters like EDV.

Signal Quality Management

Improving Signal Quality

Techniques to optimize oximetry signal quality and resolve issues.

Factors Affecting Signal

Conditions that can compromise signal quality, such as catheter issues.