17
3. Specifications and Controls
3.1 Specifications
ACW
DCW
IR
GND
CONT.
Built-in Scanner
V
V
V
-
Option
Option
(8W or 8W+8Cont.)
V
V
V
V
Option
-
V
V
V
V
Option
V
V
V
V
-
Option
-
V
V
V
V
Option
-
MODEL
SE 7430
SE 7440
SE 7441
SE 7451
SE 7452
AC WITHSTAND VOLTAGE
Output Rating
5KVAC/40mA
5KVAC/40mA
5KVAC/40mA
5KVAC/100mA
5KVAC/100mA
Output
Rating(OPT.7015)
6KVAC/30mA
6KVAC/30mA
6KVAC/30mA
6KVAC/80mA
6KVAC/80mA
Range
Resolution
Accuracy
Output Voltage, kV
0-5.00
0.01
±(1% of Setting + 0.5% of Range)
Output Voltage,
kV(OPT.7015)
0-6.00
0.01
±(1% of Setting + 0.5% of Range)
Output Frequency
50Hz/60Hz ± 0.1%, User Selectable
Output Waveform
Sine Wave, Crest Factor = 1.3-1.5
Output Regulation
±(1% of output + 5V), From no load to full load
Hi and Lo-Limit
(Total)current, mA
Auto Range
0.000-9.999
0.001
±(2% of Setting + 2 counts)
10.00-40.00
(SE 7430 , SE 7440 ,
SE 7441)
0.01
10.00-99.99
(SE 7451 , SE 7452)
±(2% of Setting + 6 counts)
100.0
(SE 7451 , SE 7452)
0.1
Fixed Range
0.000-3.500
0.001
±(2% of Setting + 2 counts)
3.51-40.00
(SE 7430 , SE 7440 ,
SE 7441)
0.01
3.51-99.99
(SE 7451 , SE 7452)
±(2% of Setting + 6 counts)
100.0
(SE 7451 , SE 7452)
0.1
Hi and Lo-Limit
(Real)current, mA
Auto Range
0.000-9.999
0.001
±(3% of Setting + 50µA)
10.00-40.00
(SE 7430 , SE 7440 ,
SE 7441)
0.01
10.00-99.99
(SE 7451 , SE 7452)
100.0
(SE 7451 , SE 7452)
0.1
Ramp Up Timer,
Second
0.1-999.9
0.1
±(0.1% of Setting + 0.05s)
Ramp Down Timer,
Second
0.0-999.9

Table of Contents