Problem Possible faults Action
Smoke from the grate at start
up.
The fan is not running. Press ( Start ).
Smoke from closed doors Seals leaky Adjust doors, replace seals.
The fan doesn´t start Faulty control panel.
Overheating protection released.
Contact Effecta.
Press the reset pin under the
hat.
Tar in the convetion area. Too much soot in the grate.
Lambda sond dirty
Dampers faulty
Clean grate
Clean lambda sond
Contact Effecta
None or little heat is transfer-
red to the accumulator.
Air in the system.
Poor wood.
Try to deair the system
Switch to better wood, or split
it ner.
The boiler gives less effect
and is hard to use
Moisty wood, to little
draft through the chimney.
The boiler needs to be cleaned.
Try wood with less moist.
Clean the boiler
The laddomat valve is bang-
ing or making strange noices,
poor ue through the system.
Air in the system,
To low pressure in the system
Try to deair the system
Increase pressure
The pressure is decreasing in
the system
You have a leak in the system.
Water have vaporised from the
open expansion vessel. Wrong
pre-pressure in the pressure
vessel.
Check for the leak.
Fill the system.
Adjust pressure.
Trouble shooting