EasyManua.ls Logo

Effecta Lambda - User Manual

Default Icon
21 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Effecta AB - Västra Rågdalsvägen 21 - 434 96 Kungsbacka - 0300 - 22320 - info@effecta.se
effecta Lambda
Operation
Service
Installation
Rev. 07-01-07

Questions and Answers

  • M
    Miss Kathryn MasonJul 27, 2025
    What to do if the pressure is decreasing in the Effecta Boiler system?
    • H
      Helen LesterJul 27, 2025
      If the pressure in your Effecta Boiler system is decreasing, it could be due to a leak, water vaporization from the open expansion vessel, or incorrect pre-pressure in the pressure vessel. Check for leaks and fill the system. You may also need to adjust the pressure.
  • S
    Sarah ZhangJul 31, 2025
    Why is the Effecta Boiler giving less effect and is hard to use?
    • D
      Danny WheelerJul 31, 2025
      If your Effecta Boiler is giving less effect and is hard to use, it could be due to moist wood, too little draft through the chimney, or the boiler needing to be cleaned. Try using wood with less moisture and clean the boiler.
  • J
    Janice HansonAug 6, 2025
    What to do if none or little heat is transferred to the accumulator in Effecta Boiler?
    • D
      davisveronicaAug 6, 2025
      If little to no heat is transferred to the accumulator in your Effecta Boiler, it might be due to air in the system or poor wood quality. Try de-airing the system or switch to better wood, or split it finer.
  • T
    Tommy BaldwinAug 10, 2025
    What to do if the laddomat valve is banging or making strange noises in Effecta Boiler?
    • K
      Karen FosterAug 11, 2025
      If the laddomat valve in your Effecta Boiler is banging or making strange noises, and there's poor flue through the system, it could be due to air in the system or low pressure. Try de-airing the system and increase the pressure.
  • G
    goodwindylanAug 15, 2025
    How to fix smoke coming from closed doors of Effecta Boiler?
    • C
      Carla LewisAug 16, 2025
      If you're experiencing smoke coming from closed doors of your Effecta Boiler, it's likely due to leaky seals. Adjust the doors or replace the seals.
  • A
    Antonio KellyAug 20, 2025
    How to stop smoke from the grate at start up of Effecta Boiler?
    • R
      Rachel LeeAug 20, 2025
      If you're experiencing smoke from the grate when starting up your Effecta Boiler, the fan may not be running. Press the Start button.

Summary

Warranty

In General

Domestic water

Explains the requirement of a coil and mixing valve for domestic hot water production.

Combustion

Describes the two air inlets controlled by motors for optimal combustion and emission reduction.

The system

Details system requirements like 1500L accumulation volume and benefits of buffertanks.

To the installer

Location

Instructions on placing the boiler on a firm foundation and maintaining distances to combustibles.

The boiler room

Requirements for the boiler room construction and ventilation for optimal performance.

The accumulator

Emphasizes the importance of well-isolated accumulators and minimum volume for comfort.

The chimney

Specifies chimney diameter, draft requirements, and condensation risks.

Components

Laddomat 21

Describes the Laddomat valve's role in connecting the boiler to the accumulator tank.

Automatic Shunt

Highlights benefits of an automatic shunt valve for temperature control and efficiency.

Expansion Vessel

Provides specifications for the expansion vessel's pressure, temperature, and volume.

Safety Valve

Explains the safety valve's function to release excess pressure above 1.5 bars.

Shuntvalve

Details the shunt valve's purpose in mixing water for desired indoor temperature.

Valve Combination

Piping

The Accumulator Tank

The Draft Stabiliser

System Overview

Placement of components

Function Laddomat 21

Connections in Solar accumulator

The Control Panel

Electrical installation

Environment

The fuel

Discusses suitable wood types, quality, and mixing for efficient combustion.

Storage of the fuel

Provides guidelines on wood moisture content and log dimensions for optimal storage.

Cannibalisation

Briefly mentions following regulations for dismantling the boiler.

The control

The menues

Covers calibration, tuning lambda value, and sooting procedures accessible via the menus.

Making a fire

Provides detailed instructions for starting and maintaining a fire in the boiler.

Sooting

Annual Service

Trouble shooting

Declaration of Conformity

Effecta Lambda Specifications

General IconGeneral
BrandEffecta
ModelLambda
CategoryBoiler
LanguageEnglish