Questions and Answers

  • D
    Donald HarperSep 4, 2025
    What to do if warning light 1 flashes quickly and lights 2, 3, 4, and 7 are on with a continuous alarm on my Effer Industrial Equipment?
    • D
      Derek KnightSep 4, 2025
      If warning light 1 flashes quickly while lights 2, 3, 4, and 7 are permanently on with a continuous alarm, the DMU is receiving an anomalous angle value related to the jib position. Replace the angular sensor.
  • C
    carlsonjadeSep 18, 2025
    What to do if the Effer Industrial Equipment was restarted too quickly after being switched off?
    • A
      Amanda TylerSep 18, 2025
      Turn off the DMU and restart it electrically after at least three seconds.
  • L
    Laurie SandersSep 16, 2025
    Why is warning light 3 flashing without an acoustic alarm on my Effer Industrial Equipment?
    • D
      dixonalexisSep 16, 2025
      If the warning light 3 flashes and no acoustic alarm is emitted, it indicates a faulty encoder for crane slewing. If fault can not be found out, get in touch with an EFFER authorized workshop immediately.
  • E
    Emily EvansSep 14, 2025
    What to do if warning light 3 flashes during the first slewing after start-up on my Effer DMU 3000 Industrial Equipment?
    • D
      Debra FreemanSep 14, 2025
      If, after switching on the unit, during the first slewing, the warning light 3 flashes, the warning lights 1, 2, 4, and 7 are lit permanently, and a continuous acoustic alarm is emitted, it means that the rotary sensor reads an uncorrect value (out of range). If fault can not be found out, get in touch with an EFFER authorized workshop immediately.
  • S
    Sean RomeroSep 13, 2025
    Why are warning lights 1, 2, 3, and 7 flashing with an intermittent alarm related to the electronic hook on my Effer DMU 3000 Industrial Equipment?
    • T
      Teresa OliverSep 13, 2025
      If warning lights 1, 2, 3, and 7 flash in sequence with an intermittent alarm related to the electronic hook, possible causes include: 1) Low pin battery. 2) Communication error between DMU and pin. 3) Radio communication error between pin and its receiver. Charge or replace the pin battery using the appropriate cable.
  • S
    samuelpenaSep 12, 2025
    What causes issues when slewing into a downgraded work area on my Effer DMU 3000?
    • U
      utravisSep 12, 2025
      If issues arise when slewing into a downgraded work area controlled by two proximity switches, there's a short circuit in the electrical wiring. Replace the proximity switches.
  • P
    Patricia SalazarSep 9, 2025
    Why is warning light 1 flashing quickly and lights 2, 3, 4, and 7 are permanently lit with a continuous alarm on my Effer DMU 3000 Industrial Equipment?
    • K
      kellybrownSep 9, 2025
      If warning light 1 flashes quickly, and warning lights 2, 3, 4, and 7 are permanently lit accompanied by a continuous alarm, it means the DMU is not receiving any pressure/angle value relating to the jib. Restore the electric connection.
  • D
    David FletcherSep 7, 2025
    What to do if warning light 1 flashes quickly even though the jib is not fitted on my Effer DMU 3000 Industrial Equipment?
    • R
      rodriguezbreannaSep 7, 2025
      If warning light 1 flashes quickly, lights 2, 3, 4, and 7 are on, and there's an intermittent alarm, even though the jib isn't fitted, the DMU is still receiving a pressure value from the jib cylinder. Replace the electronic card.
  • K
    Kevin WilliamsSep 5, 2025
    Why is warning light 2 flashing quickly while lights 1, 3, 4, and 7 are on with a continuous alarm on my Effer DMU 3000 Industrial Equipment?
    • L
      Lindsay MillerSep 6, 2025
      If warning light 2 flashes quickly and warning lights 1, 3, 4, and 7 are on permanently accompanied by a continuous alarm, the DMU is receiving an anomalous angle value related to the second boom position. Replace the angular sensor.
  • T
    Todd FieldsAug 21, 2025
    What to do if warning lights 1, 2, 3, 4, and 7 are permanently lit on my Effer Industrial Equipment?
    • K
      Kelly MooreAug 21, 2025
      If warning lights 1, 2, 3, 4, and 7 are permanently lit without an acoustic alarm, it indicates a short circuit between the DMU and a solenoid valve on the crane (HSS, main discharge, first boom discharge, etc.). Restore the solenoid valve's electrical connections. If the problem persists, the DMU central unit may need replacement.

Summary

Installing the DMU Software

Connecting the Computer to the Crane

Communication Port Settings

Changeable Parameters Explanation

Load Limiting Device Adjustments

Parameters for adjusting load limits and crane operation.

Boom, Jib & Downgrading Settings

Configuration settings for boom, jib, and performance downgrading.

Displaying and Changing Software Data

DMU Diagnostics Instructions

Sensors Diagnostic and DMU hardware

Analyzes sensors and DMU hardware for faults.

Control Bank Lever Diagnostics

Checks the functionality of the control bank levers.

Adjusting Angle Sensors

Entering New Parameters for Crane Configuration

Overload Test Procedure

DMU Diagnostics and Troubleshooting

Lever Operation Errors

Faults related to control bank lever position and operation.

Sensor Errors (Pressure & Angle)

Faults detected in pressure and angle sensors.

Communication and Connection Errors

Errors related to short circuits and communication failures.

Operational Blockage Errors

Errors causing crane blockage or specific warning light patterns.

Checking Wiring Functionality