Questions and Answers

  • D
    deborah86Sep 4, 2025
    What to do if warning light 1 flashes quickly and lights 2, 3, 4, and 7 are on with a continuous alarm on my Effer DMU 2000?
    • R
      rebeccadawsonSep 4, 2025
      If warning light 1 flashes quickly while lights 2, 3, 4, and 7 are permanently on with a continuous alarm, the DMU is receiving an anomalous angle value related to the jib position. Replace the angular sensor.
  • A
    Ashley YoungSep 18, 2025
    What to do if the Effer Industrial Equipment was restarted too quickly after being switched off?
    • D
      Dr. Savannah MurphySep 18, 2025
      Turn off the DMU and restart it electrically after at least three seconds.
  • H
    Henry StevensonSep 16, 2025
    Why is warning light 3 flashing without an acoustic alarm on my Effer DMU 2000 Industrial Equipment?
    • J
      Joshua BeanSep 16, 2025
      If the warning light 3 flashes and no acoustic alarm is emitted, it indicates a faulty encoder for crane slewing. If fault can not be found out, get in touch with an EFFER authorized workshop immediately.
  • J
    jeremy02Sep 14, 2025
    What to do if warning light 3 flashes during the first slewing after start-up on my Effer Industrial Equipment?
    • M
      Megan JordanSep 14, 2025
      If, after switching on the unit, during the first slewing, the warning light 3 flashes, the warning lights 1, 2, 4, and 7 are lit permanently, and a continuous acoustic alarm is emitted, it means that the rotary sensor reads an uncorrect value (out of range). If fault can not be found out, get in touch with an EFFER authorized workshop immediately.
  • C
    Carmen WrightSep 13, 2025
    Why are warning lights 1, 2, 3, and 7 flashing with an intermittent alarm related to the electronic hook on my Effer Industrial Equipment?
    • L
      laurenjonesSep 13, 2025
      If warning lights 1, 2, 3, and 7 flash in sequence with an intermittent alarm related to the electronic hook, possible causes include: 1) Low pin battery. 2) Communication error between DMU and pin. 3) Radio communication error between pin and its receiver. Charge or replace the pin battery using the appropriate cable.
  • L
    Laura FloresSep 12, 2025
    What causes issues when slewing into a downgraded work area on my Effer DMU 2000?
    • J
      Jennifer JohnsonSep 12, 2025
      If issues arise when slewing into a downgraded work area controlled by two proximity switches, there's a short circuit in the electrical wiring. Replace the proximity switches.
  • G
    Gerald MaynardSep 9, 2025
    Why is warning light 1 flashing quickly and lights 2, 3, 4, and 7 are permanently lit with a continuous alarm on my Effer Industrial Equipment?
    • E
      Emily Edwards MDSep 9, 2025
      If warning light 1 flashes quickly, and warning lights 2, 3, 4, and 7 are permanently lit accompanied by a continuous alarm, it means the DMU is not receiving any pressure/angle value relating to the jib. Restore the electric connection.
  • J
    James NewtonSep 7, 2025
    What to do if warning light 1 flashes quickly even though the jib is not fitted on my Effer DMU 2000?
    • M
      Megan WalshSep 7, 2025
      If warning light 1 flashes quickly, lights 2, 3, 4, and 7 are on, and there's an intermittent alarm, even though the jib isn't fitted, the DMU is still receiving a pressure value from the jib cylinder. Replace the electronic card.
  • A
    audrey73Sep 6, 2025
    Why is warning light 2 flashing quickly while lights 1, 3, 4, and 7 are on with a continuous alarm on my Effer DMU 2000 Industrial Equipment?
    • A
      Alexa NelsonSep 6, 2025
      If warning light 2 flashes quickly and warning lights 1, 3, 4, and 7 are on permanently accompanied by a continuous alarm, the DMU is receiving an anomalous angle value related to the second boom position. Replace the angular sensor.
  • D
    deborahmooreAug 21, 2025
    What to do if warning lights 1, 2, 3, 4, and 7 are permanently lit on my Effer Industrial Equipment?
    • T
      tiffany42Aug 21, 2025
      If warning lights 1, 2, 3, 4, and 7 are permanently lit without an acoustic alarm, it indicates a short circuit between the DMU and a solenoid valve on the crane (HSS, main discharge, first boom discharge, etc.). Restore the solenoid valve's electrical connections. If the problem persists, the DMU central unit may need replacement.

Summary

DMU System Overview and Setup

Introduction to DMU Devices and Glossary

Overview of DMU devices and a glossary of technical terms used in the manual.

Software Installation and Basic Operation

Detailed steps for installing the DMU software and initial operational procedures.

DMU Configuration and Parameter Adjustment

Communication Ports and Parameter Settings

Instructions for setting up communication ports and configuring DMU parameters.

Adjusting Load Limiting and Derating Parameters

Explanation and adjustment of parameters related to load limiting and performance derating.

Configuring Safety Devices and Angle Sensors

Settings for safety devices, anti-bridge height, and angle sensor adjustments.

Data Management and Testing Procedures

Displaying, Changing, and Printing DMU Data

Procedures for displaying, modifying, and printing DMU data sheets.

Overload Testing Procedures

Guidance on performing dynamic and static crane overload tests.

DMU System Diagnostics

Sensors, Hardware, and Lever Diagnostics

Diagnostic menus for sensors, DMU hardware, and control bank levers.

Interpreting Panel Indicators for Faults

Understanding DMU panel lights and sounds for fault identification.

DMU Troubleshooting and Fault Resolution

Troubleshooting Sensor and Communication Faults

Resolving issues related to pressure sensors, angle sensors, and communication errors.

Troubleshooting Operational Errors and Alarms

Resolving faults related to operational errors, warning lights, and acoustic alarms.

Wiring and Component Verification

Checking Wiring Functionality and Simulating Components

Methods for checking wiring integrity and simulating sensor inputs.