Installation Instructions
CAUTION:
1. Installer must be a trained, experienced serviceman.
2. Inspect the boiler, jacket and all components to be sure damage has not occurred in shipment. If
damage is evident you must file a claim with the freight carrier immediately.
3. Disconnect power supply before connecting wiring.
4. Refer to local installation codes for oil burning equipment, for recommended installation practice.
5. A complete heat loss calculation is necessary to choose the proper size unit to install. The boiler
should be sized to within 25% of the actual heat loss of the structure.
6. Conduct thorough checkout when installation is complete.
1) Place the boiler on a level non-combustible
floor, preferably raised and as close to the
chimney as possible. The following minimum
clearances must be adhered to during instal-
lation and maintained thereafter to properly
clean, inspect and service your boiler: sides
and back - 6"; front - 24" and vent connector
18". Reduced clearance installations must
follow NFPA-31 guidelines.
2) For location of piping refer to the installation
drawing in Figure 5 and 6. The circulator is
shipped loose. Wire the circulator as shown
on the wiring diagrams in this manual. The
Specifications
HEATING NET NET WATER SMOKE SHIPPING
NOZZLE SIZE BECKETT CHIMNEY
MODEL CAPACITY OUTPUT OUTPUT CAPACITY OUTLET WEIGHT
GPH + TYPE BURNER SIZE
BTUH BTUH SQ. FT. GAL. SIZE POUNDS
1.00 - 80 H 116,000 100,000 664
0.85 - 80 H 100,000 86,000 570
VT 700 E AFG76XN 968X8X15 315
0.75 - 80 H 88,000 77,000 510
0.65 - 80 H 77,000 67,000 444
1.65 - 80 H 193,000 166,000 1,107
1.50 - 80 H 174,000 151,000 1,006
VT 1000 E AFG76YB 19 7 8X8X15 435
1.35 - 80 H 159,500 137,000 915
1.10 - 80 H 131,500 113,000 754
______________________________________________________________________________________
_____________________________________
_____________________________________
_____________________________________
______________________________________________________________________________________
_____________________________________
_____________________________________
_____________________________________
Installation Instructions
Boiler Burner Unit
Model VT 700 E
Model VT 1000 E
(For Hot Water Heating Systems)
e
f
m
Sales Company
Emmaus, Pennsylvania
Question and Answer IconNeed help?

Do you have a question about the EFM Heating VT 700 E and is the answer not in the manual?

EFM Heating VT 700 E Specifications

General IconGeneral
BrandEFM Heating
ModelVT 700 E
CategoryBoiler
LanguageEnglish