EasyManua.ls Logo

Egcon AVR-126 - Troubleshooting; Residual Voltage - No Output

Egcon AVR-126
7 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6

 

9. TROUBLE SHOOTING
SYMPTOM CAUSE ACTION
Residual Voltage-
No Output
Residual voltage at regulator
power input wires 3 & 4 below 3Vac.
Field leads F+, F- not connected.
Power input leads not connected.
Blown or missing fuse.
Defective regulator.
Defective generator.
Check wiring diagram for proper
Connections.
Flash generator field. Refer to 7.FLASH
EXCITING section in generator manual.
Connect field lead F+, F-.
Connect power input leads 3, 4.
Replace fuse.
Replace regulator.
Consult generator manual.