© 2016 - 2017, Euro Games Technology Ltd. 63
HARDWARE
V.1.1. Fuse Replacement
During the operation of the Gaming Machine it may become necessary to
replace F1 or F2 fuses. For this purpose the machine power plug must be
unplugged from the power mains socket! The new fuses must be with the
same parameters as the original ones: T6.3A/ 250 V for F1 and F2.
V.2.1. Events, Only Registered in “All Events Log”
AC power applied - Logged at powering on the machine. Date and time of powering on is
logged.
AC power lost - Logged when the AC power is lost. Date and time of losing AC power is
logged.
AFT registration acknowledged - Logged when AFT registration is acknowledged.
AFT registration canceled - Logged when AFT registration is canceled.
AFT request register - Logged when AFT request is registered.
AFT transfer complete - Logged when AFT transfer is complete. The amount and type of
transfer are logged.
Bill 1 accepted - Logged when a bill of par value 1 is accepted.
Bill 10 accepted - Logged when a bill of par value 10 is accepted.
V.1. TROUBLESHOOTING
External features Possible cause Solution
Nothing lights up
Fuse burned out Replace fuse
Power Cord Replace power cord
Main Power Supply Unit
(PSU)
Check PSU LED. Replace PSU.
Buttons don’t work
Defective button Replace the button
Problems with connection
to keyboard controller
Check keyboard controller connections.
Electromechanical Meters
Defective meter Replace meter
Problems with connection
to meters controller
Check meters controller connections
Touchscreen does not
work
Problems with connection
between controller and
control computer.
Check the connection cable and re-
place if necessary.
Touchscreen controller de-
fective
Replace Touchscreen controller
No sound and picture,
only decorative lighting
works
Problems with the control
computer.
Check the power of control computer.
Check the game platform
Replace defective modules.
V.2. ERROR MESSAGES