24
6. Replace the wiring cover and carefully line up the Alarm on the base and slide on (see Figure 7).
7. Connect the mains power to the Alarm circuit. Check the green light on the front of the Alarm is on.
8. Press and hold the test/hush button for 10 seconds (see Figure 8). The horn will sound. Check that
any interconnected Alarms also sound within this period. The test button sounds the local horn and
on release this horn stops immediately, and all the interconnected Alarms can then be heard in the
distance as they will continue to sound for a further 3 seconds.
9. Attach the ’fuse board label’ provided on or near the distribution board and write in date installed
and the number of Alarms on the circuit.
10. Ensure the Alarm operates correctly - see TESTING and MAINTAINING YOUR ALARM section.
Slide on the Alarm
Test Alarms
Fig.7 Fig.8