EasyManua.ls Logo

EINHELL bavaria BHR 100F - User Manual

EINHELL bavaria BHR 100F
38 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Bedienungsanleitung
Hochdruckreiniger
Operating Instructions
High-Pressure Cleaner
Mode d’emploi
Nettoyeur haute pression
Gebruiksaanwijzing
hogedrukreiniger
Istruzioni per l’uso
Idropulitrice
Руководство по эксплуатации
высоконапорно“о гидроочистителя
Használati utasítás
nagynyomású tisztító
Naputak za uporabu
Visokotlačni čistač
BHR 100F
Art.-Nr.: 41.404.20 I.-Nr.: 01012
®
Das Gerät nicht in Betrieb nehmen, ohne die
Gebrauchsanleitung gelesen zu haben!
Please read these instructions carefully before
installing and operating the high-pressure cleaner!
Ne mettez pas l’appareil en service sans avoir lu ce
mode d’emploi !
Het toestel niet in bedrijf stellen zonder de
gebruiksaanwijzing te hebben gelezen!
Non mettere in funzione l’apparecchio prima di
avere letto le istruzioni per l’uso!
Нельзя приступать к работе с устройством не
прочитав руководства по эксплуатации!
H Ne üzemeltese a készüléket, anélkül hogy előtte
elolvasta volna a használati utasítást!
Ne uključujte ovaj aparat dok niste pročitali
naputak za uporabu!
Anleitung_BHR100 F SPK 1 27.02.2003 9:39 Uhr Seite 1

Questions and Answers

  • G
    garrett01Aug 16, 2025
    Why is there a loss of pressure in my EINHELL bavaria BHR 100F Pressure Washer?
    • R
      robbinscatherineAug 16, 2025
      If your EINHELL Pressure Washer experiences a loss of pressure, the issue might stem from several causes. The nozzle could be worn, or the valves might be dirty or clogged. Additionally, the valve seals or other seals could be worn, and the filter might be clogged. To address this, try changing the nozzle. Also, check, clean, or replace the valves, valve seals, and other seals as needed, and inspect and clean the filter.
  • M
    Matthew RobinsonAug 19, 2025
    How to troubleshoot an EINHELL bavaria BHR 100F when the electric pump doesn't start?
    • M
      Matthew YoungAug 19, 2025
      If your EINHELL Pressure Washer's electric pump isn't running when you press the switch, several factors could be at play. The plug might be damaged, there could be insufficient voltage, the pump might be locked, or the thermal relay could have triggered. Check the plug and fuses to ensure they're in good condition. Manually turn over the motor. Allow the motor to cool down.
  • D
    Dr. Eric EllisAug 22, 2025
    What to do if my EINHELL bavaria BHR 100F Pressure Washer motor suddenly stops?
    • M
      Michael ColemanAug 22, 2025
      If the motor of your EINHELL Pressure Washer suddenly stops, it could be due to the thermal relay being triggered by overheating. To resolve this, check the voltage. Turn off the switch and allow the motor to cool down for a few minutes.
  • M
    Molly Blair DDSAug 26, 2025
    Why is my EINHELL bavaria BHR 100F making excess noise?
    • J
      James WalkerAug 26, 2025
      Excess noise in your EINHELL Pressure Washer can be attributed to several factors. Air may be getting drawn in, or the valves might be worn, dirty, or clogged. The bearings could also be worn, the water temperature might be too high, or the filter might be dirty. Check the intake lines, and inspect, clean, or replace the valves. Also, check and/or exchange the bearings. Lower the water temperature to below 60 °C and inspect and/or exchange the filter.
  • R
    Russell WrightAug 28, 2025
    What to do if EINHELL bavaria BHR 100F Pressure Washer pump runs but doesn't generate pressure?
    • D
      David ByrdAug 28, 2025
      If the electric pump runs but no pressure is generated in your EINHELL Pressure Washer, it could be due to a clogged intake filter, air being drawn in at the connectors, clogged or worn inlet and outlet valves, or the nozzle hole diameter being too large. Clean the filter, check the intake connection fitting and hose connectors. Clean or replace the valves. Check and replace the nozzle.
  • C
    Christopher ClarkAug 31, 2025
    Why is the operating pressure of my EINHELL bavaria BHR 100F Pressure Washer irregular?
    • K
      Kristen SullivanAug 31, 2025
      Irregular operating pressure in your EINHELL Pressure Washer can occur if air is being drawn in, or if the valves are clogged and worn, or if the seals are worn. Inspect the intake connectors. Clean and replace the valves. Check and replace the seals.
  • D
    Daniel RichardsonSep 3, 2025
    Why is water leaking from the pump head of my EINHELL Pressure Washer?
    • N
      Natalie HarrisSep 3, 2025
      If water leaks from the pump head of your EINHELL Pressure Washer, it's likely due to worn seals or a worn O-ring in the seal set. Exchange the seal. Exchange the O-ring.
  • B
    Brian CastroSep 6, 2025
    What to do if my EINHELL Pressure Washer motor hums but doesn't start?
    • R
      richard13Sep 6, 2025
      If, when you press the switch on your EINHELL Pressure Washer, the motor hums but doesn't start, it could be due to several reasons: the mains voltage might be lower than specified, the pump could be blocked or frozen, or the extension cable might be insufficient (either the cross section is too small, or the cable is too long). Check to see that the extension cable is sufficient and exchange the extension cable for one that is sufficient.
  • B
    Brittany SimpsonSep 9, 2025
    Why is the water from my EINHELL Pressure Washer mixed with oil?
    • C
      Casey ArmstrongSep 9, 2025
      If the expelled water from your EINHELL Pressure Washer is mixed with oil, it indicates that the sealing rings (water + oil) are worn. Check and/or exchange them.
  • R
    Robin AndrewsSep 12, 2025
    Why is my EINHELL bavaria BHR 100F Pressure Washer pump dripping?
    • S
      Stephanie BakerSep 12, 2025
      If your EINHELL Pressure Washer pump is dripping, it is likely due to worn seals. Check and replace them, preferably at a professional repair shop.

EINHELL bavaria BHR 100F Specifications

General IconGeneral
Operating pressure70 bar
Max. pressure100 bar
Flow rate360 L/h
Max. water temperature40 °C
Voltage230 V
Frequency50 Hz
Hose Length5 m