10. Troubleshooting
Problem Possible causes Solution
Motor does not start
or comes to a stop
(loose connection).
a) Motor terminals disconnected.
b) The mower is standing in high
grass.
c) The mower housing is clogged.
d) Safety plug is not inserted.
e) Battery is not correctly inserted.
a) Have repaired by service center.
b) Start in low grass or on an area that
has already been mowed; change
the cutting height if necessary.
c) Clean the housing so that the blade
moves freely.
d) Insert safety plug (see 6).
e) Remove the battery and reinsert
(see 5).
The drive motor
does not start.
a) Motor terminals disconnected.
b) Machine standing in high grass.
c) The mower housing is clogged.
d) Safety plug is not inserted.
e) Battery is not correctly inserted.
f) Thermal cut-out switch has tripped.
a) Have it checked by a customer
service workshop.
b) Start motor on shorter grass or
already mowed area; change
cutting height if necessary.
c) Clean housing so that the blade
can run freely.
d) Insert the safety plug (see 6.).
e) Remove the battery and reinsert
(see 5.).
f) Let the equipment cool down for at
least 10 minutes.
The motor
performance drops.
a) The grass is too high or too damp.
b) The mower housing is clogged.
c) The blade is severely worn.
d) Battery performance
decreasing.
a) Correct the cutting height.
b) Clean the housing.
c) Replace the blade.
d) Check the battery performance-
and charge the battery if necessary
(see 5).
Cutting is irregular. a) The blade is worn.
b) Wrong cutting height.
a) Replace or re-sharpen the blade.
b) Correct the cutting height.
Notice! For protection, the motor is equipped with a thermal switch which cuts out when the
motor is overloaded and switches on again automatically after a short cooling period.
Anl_GP_CM_36_52_S_Li_BL_SPK7_NA.indb 19Anl_GP_CM_36_52_S_Li_BL_SPK7_NA.indb 19 21.11.2023 10:57:5921.11.2023 10:57:59