11. Troubleshooting guide
Fault Possible causes Recti cation
Motor does not start - No electricity in plug
- Cable defective
- Switch, switch/plug block defec-
tive
- Connections to motor or capacitor
disconnected
- Housing clogged
- Check line and fuse
- Check
- Have machine checked by a cus-
tomer service center
- Have machine checked by a cus-
tomer service center
- If necessary adjust working depth.
Clean housing so that the roller can
run freely
Engine performance
drops
- Soil is too rm
- Housing clogged
- Roller badly worn
- Change working depth
- Clean housing
- Replace roller
Imprecise scarifying
result
- roller worn
- Wrong working depth
- Replace roller
- Correct working depth
Motor is running,
roller is not rotating
- Toothed belt is torn - By customer service workshop
Danger! To protect the motor itis equipped with a thermal overload switch which cuts out when
overloaded and starts again automatically after a short cooling-down period.
Anl_RG-SA_1433_SPK9.indb 26Anl_RG-SA_1433_SPK9.indb 26 31.03.2017 09:18:0531.03.2017 09:18:05