11. Possible causes of failure
Problem Cause Solution
The compressor
does not start.
1. No supply voltage.
2. Insu cient supply voltage.
3. Outside temperature is too low.
4. Motor is overheated.
1. Check the supply voltage, the pow-
er plug and the socket-outlet.
2. Make sure that the extension cable
is not too long. Use an extension
cable with large enough wires.
3. Never operate with an outside tem-
perature of below +5° C.
4. Allow the motor to cool down. If
necessary, remedy the cause of the
overheating.
The compressor
starts but there is no
pressure.
1. The non-return valve leaks.
2. The seals are damaged.
1. Have a service center replace the
non-return valve.
2. Check the seals and have any da-
maged seals replaced by a service
center.
The compressor
starts, pressure is
shown on the pres-
sure gauge, but the
tools do not start.
1. The hose connections have a leak.
2. A quick-lock coupling has a leak.
1. Check the compressed air hose
and tools and replace if necessary.
2. Check the quick-lock coupling and
replace if necessary.
Anl_TC_AC_180_8_OF_SPK9.indb 26Anl_TC_AC_180_8_OF_SPK9.indb 26 21.01.2019 08:35:0121.01.2019 08:35:01

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the EINHELL TC-AC 180/8 OF and is the answer not in the manual?

EINHELL TC-AC 180/8 OF Specifications

General IconGeneral
BrandEINHELL
ModelTC-AC 180/8 OF
CategoryAir Compressor
LanguageEnglish

Related product manuals