Technical data
6. Technical data
Connections
o Connection between inside and outside unit
o 1x (3x version TOCAaccess light+) relay 250V~ 5A
o 9VAC with supplied external adaptor
Memory
o 99 fingers possible
o No loss of data after power failure
Security
o Coupling between inside and outside unit
o Extremely low rate of false identification
power consumption
o max. 7W
Speed
o Recognition time <20ms per stored finger
o Enrolment time ~1,2s per finger
Recommended diameters of the wires:
Length of wire Min. diameter of the lines Type
< 20 m 0,75mm² unscreened
> 20m Diameter of the wire has to be enlarged accordingly screened cable