EasyManuals Logo

EKF Diagnostics Biosen C-Line GP+ User Manual

Default Icon
123 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #55 background imageLoading...
Page #55 background image
Technical Data
User Manual Biosen C_line Clinic / GP+
51
14. Technical Data
Measurement principle
Enzymatic - amperometric
Measurement range
Glucose: 0,5-50 mmol/l (9-900 mg/dl)
Lactate: 0,5-40 mmol/l (5-360 mg/dl)
Accuracy
CV ≤ 1,5% at 12 mmol
Stability (drift)
≤ 3% over 10 tests, based on 12 mmol/L
Lifetime of the sensor
(on average)
Glucose: 60 days or 7500 tests
Lactate: 50 days or 6000 tests
Sample material
Blood, plasma or serum
Sample volume
20 µl
ambient conditions during operation
Temperature
Relative humidity
+15°C to +35°C
20% to 85%
ambient conditions during storage and transport
Temperature
Relative humidity
-20°C to +50°C
20% to 85%
Mains power
100 240VAC 50/60Hz
Fuse
2 x T315mA H250V
Power consumption
30VA
Dimensions (LxWxH)
280 x 280 x 95mm
Weight
Ca. 4,5 kg
EDP
RS 232C
Printer
RS 232C
Display / keyboard
Graphic touch panel (320 x 240 Pixel)
Memory
1000 values

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the EKF Diagnostics Biosen C-Line GP+ and is the answer not in the manual?

EKF Diagnostics Biosen C-Line GP+ Specifications

General IconGeneral
BrandEKF Diagnostics
ModelBiosen C-Line GP+
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals